Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
causative bacteria hazard degree causative bacteria causative bacteria laboratory causative bacteria laboratories causative bacteria causative bacteria laboratories chinastandards.net subacute toxicity test scopethis standard mine car shaft multi-rope cage scopethis standard grey fabrics introduction background
WS 233-2017 in English

WS 233-2017 in English

VALID

General biosafety standard for causative bacteria laboratories

  • Issued on:2017-07-24
  • Implemented on:2018-02-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $600.00
$582.00
Standard No: WS 233-2017
Document status: VALID
Title in English: General biosafety standard for causative bacteria laboratories
Title in Chinese: 病原微生物实验室生物安全通用准则
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2017-07-24
Implemented on: 2018-02-01
Superseding: WS 233-2002 General biosafety standard for microbiological and biomedical laboratories
ICS Classification: 11.020-Medical Sciences and health care facilities in general
Chinese Classification: C59-
Professional Classification: WS-Hygiene
Related Keywords: causative bacteria hazard degree causative bacteria
causative bacteria laboratory
causative bacteria laboratories
causative bacteria
causative bacteria laboratories chinastandards.net
Related Topics: Biological suite of laboratories
pathogen
Pathogenic microorganisms
Biosecurity
Biology laboratory
Original suction laboratory
Biological laboratory related
Microbiological Safety Laboratory
Biological suite of laboratories
microbiology laboratory
Microbial experiment
Standard Biosafety Laboratory
Domestic biological testing laboratory
biological laboratory complete set
Biological complete set of laboratory equipment
laboratory bioactivity test
ws233 2017
iso biological laboratory
Pathogenic Microbiology Laboratory
Pathogenic Microbiology Laboratory
Biomolecular Laboratory
iso biological laboratory
Standard biological laboratory
Biological complete set of laboratory equipment
Rapid detection of pathogenic microorganisms
microbiology laboratory
laboratory biology
Laboratory biotoxicity meter
Laboratory biotoxicity meter
laboratory biosafety
Biology laboratory
Frontier Lab Equipment Biology
microbial organisms
Trace Substance Analysis Laboratory
Number of biological laboratories
Bioanalytical Laboratories and Central Laboratories
Pathogenic microorganisms
Biomarker Laboratory
Comorbidity Laboratory
Biological experiments
biological laboratory
Compound principle
ws233-2017
Health Standards Laboratory
Biological laboratory scale
Biological laboratory scale
Number of biological laboratories
atomic experiment
Molecular Biology Laboratory
Microbial Culture Laboratory
Domestic Laboratory Safety
micro experiment
Standard Biology Laboratory
laboratory antigen
Molecular Biology Laboratory
Pathogenic microorganisms
Level Biology Lab
Biosafety Level 4
Biodiversity Lab
laboratory in bioengineering
Bioengineering experiment
experiments in bioengineering
Bioengineering experiment
Biological experiments
biological laboratory analysis
Rapid Biolab System
Rapid Biolab Analysis
Microbiology laboratory instrument
atomic laboratory
Microbiology laboratory instrument
Product Microbiology Laboratory
Microbiology Laboratory Statistics
Microbiological Testing Laboratory
Rapid Microbiology Laboratory System
biological laboratory system
Microbiology Laboratory System
Microbiology Laboratory System
Data Security Lab
Biosafety Level 3
Portable Microbiology Laboratory
Principles of Laboratory Requirements
Microbial experiment
Pathogenic microbiology laboratory biosafety
Equipment for biosafety laboratories
Foodborne Pathogenic Microorganisms Thirteenth Five-Year Plan
Organic Lab Safety
biological experiment
Complete set of biological laboratory equipment
microbes
laboratory security data security
Automated Microbiological Laboratory Analysis
Industrial Microbiology Experiment
Industrial Microbiology Experiment
Microbiology Laboratory Analysis
Number of biological laboratories
Laboratory Biomass
product laboratory
micro lab
Biological series laboratory equipment
laboratory infection
Biosafety Level 4 Laboratory
Biotoxicity Laboratory
Biological simulation laboratory
Level 4 Biology Laboratory
atomic experiment
Biotoxicity Laboratory
Pathogenic microorganism test
Laboratory Spring Festival Safety
simulated biology laboratory
Level 3 Biosafety Laboratory
Microorganisms and pathogenic microorganisms
microbial pathogenic microorganism
Mobile Biosafety Level 3 Laboratory
Microbial use
biological experiment box
Biological series laboratory equipment
Biological simulation laboratory
laboratory area
Principles of Laboratory Requirements
laboratory items
Pathogenic microorganism inspection
Level 100 biological laboratory
Domestic Bioanalysis Laboratory
electronics lab safety
Standard Bioanalysis Laboratory
Prototrophs
Bioactivity Laboratory
microbiology lab experiment
Indoor microbial testing
ws2017
Bioinformatics Laboratory
Level 4 Biosafety Laboratory
Level 1 Biosafety Laboratory
Outside of biological experiments
Principles of Microbiological Testing
Principles of Microbiological Testing
domestic biological laboratory
Bioanalytical Laboratory Central Laboratory
Laboratory Safety Abroad
laboratory micropump
laboratory micropump
Microbiology laboratory routine
Quality Microbiology Laboratory
Frontier Biology Lab
General guidelines for biosafety in pathogenic microorganism laboratories
biological laboratory production
microbe + chamber
Biosafety Level 4
Physics Lab Safety
Baidu Security Lab
level laboratory
world-class biological laboratory
One-stop biological testing laboratory
pathogenic microorganisms
What is the basis for detecting pathogenic microorganisms
Pathogenic microorganism detection gold
Pathogenic Microbiology Laboratory p1
Biological experiment tank
Laboratory Animals and Biosafety
Biotransformation Laboratory
Biotoxicity lab?
biological public laboratory
Zetian Laboratory
microbiology lab experiment
Laboratory Microbial Culture
High Voltage Laboratory Safety Rules
Jiangbei biological laboratory quality
ws233
Pathogen laboratory
Microbiology room
Zetian Laboratory
multiplex pcr pathogenic microorganisms
Australian Biolabs
laboratory microbiological analysis
biological laboratory system
Physics Microlab
Microbial Dynamics Experiment
Bridgehead Biological Laboratory
First-class biological laboratory
Laboratory Microbiology Technology
flow biosafety
Experiments on Microbiology
How to clean the microbiology laboratory
laboratory positive pressure
Microbial inoculation experiment
Daily life in the biological laboratory
lab student
Frontiers of pathogenic microorganisms
Microbial inoculation experiment
principles of microbiology
Sequencing of pathogenic microorganisms
General Devices (Biosafety)
General Requirements for Laboratory Biosafety (GB19489-2019)
Microorganisms | Pathogenic microorganisms | Environmental microorganisms | Pathogenic microorganism inspection |
National Key Laboratory of Electromagnetic Space Safety
National Microbiology Laboratory of Agriculture
Biomass New Materials Laboratory
Laboratory biosafety cabinet placed in clean room
General biological official website
Microbiology laboratory sedimentation bacteria
Microbiology laboratory mold room
Microbial G experiment and GM experiment
The role of PEG8000 in biological experiments
Key Laboratory of Conservation and Biosafety
Application of biological safety cabinets in positive laboratories
Experimental principles of biological testing materials
Commonly used microorganisms in laboratories
State Key Laboratory of Pathogenic Microbiology Biosafety
Liutong pathogenic organisms
Secondary Microbiology Laboratory Functions
Microbiology experiments without sterile water
Antu microbial mass spectrometer
Laboratory safety tips
Pathogenic microorganism ngs detection
Zhijiang Laboratory Microbiology
How many biological laboratories are there in China?
National classification of laboratory biosafety
Laboratory safety related
Design of buffer room in pathogenic microbiology laboratory
Biological laboratory specimen usage techniques
Bio oil safety
Microbiology laboratory indoor quality control industry
Laboratory biosafety cabinet sedimentation bacteria test
Microbiology experiment water
Biology laboratory brush
Biosafety filing for pathogenic microbiology laboratories
Laboratory biochemical water
Comparison method between microbiology laboratories
Medical sterile biological laboratory
Is the laboratory safe?
Biosafety laboratory airtight design
Practical practice of commonly used methods for microbiological testing
Laboratory hydrogen generator safety
Microbiology laboratory design specifications and
Laboratory safety standardization
Foreign laboratory safety
Microbiology laboratory national industry
Microbiology laboratory water
About laboratory general rules
Pathogen laboratory
Rejection of specimens by biological laboratories
Observation methods and experimental principles of microorganisms


ChinaStandards.net is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative.

All contents of this standard are mandatory.

This standard is developed in accordance with the rules given in GB/T 1.1-2009.

This standard replaces WS 233-2002 General Biosafety Standard for Microbiological and Biomedical Laboratories which shall be abolished from the implementation date of this edition.

There are the following main modifications with respect to WS 233-2002:

——"Terms and Definitions" is modified (see Chapter 2; Chapter 3 of Edition 2002);

——The basic principles and requirements for laboratory biosafety protection are modified; detailed provisions regarding laboratory facility, design, environment, apparatus, personnel management, operation specification, disinfection and sterilization and the like are provided (see Chapters 4, 5, 6 and 7; Chapters 4, 5, 6 and 7 of Edition 2002);

——Risk assessment and risk control are modified (see Chapter 5; 4.7 of Edition 2002);

——Enhanced BSL-2 laboratory is added (see 6.3.2);

——Biosafety design principles, basic requirements and the like for vertebrate laboratory are modified (see 6.6.1, 6.6.2, 6.6.3 and 6.6.4; Chapter 7 of Edition 2002);

——Basic requirements for invertebrate laboratory biosafety are added (see 6.6.5);

——"Disinfection and sterilization" is added (see 7.7);

——Annexes of Edition 2002 are deleted (see Annexes A, B and C of Edition 2002);

——Informative Annexes A, B, C and D are added.

The previous edition replaced by this standard is as follows:

——WS 233-2002.
General Biosafety Standard for Causative Bacteria Laboratories

1 Scope

This standard specifies the basic principles, classification and basic requirements for biosafety protection of causative bacteria laboratories.

This standard is applicable to laboratories carrying out activities such as bacteria-related research, teaching, testing and diagnosis.

2 Terms and Definitions

For the purposes of this document, the following terms and definitions apply.

2.1

laboratory biosafety

it refers to that the biosafety conditions and state in the laboratory are not lower than the permissible level; unacceptable damage to laboratory personnel, visitors, communities and environment can be avoided; and requirements of relevant laws, regulations and standards for laboratory biosafety responsibilities can be satisfied

2.2

risk

the integrity of danger occurrence probability and its result severity

2.3

risk assessment

the whole process to assess risk and determine whether it is acceptable

2.4

risk control

the comprehensive measures adopted for reducing risks

2.5

personal protective equipment; PPE

the apparatus and articles that prevent personnel and individual from harm of biological, chemical or physical hazard factor

2.6

biosafety cabinet; BSC

the control cabinet with pneumatic control and high-efficient air filtration unit; which may effectively reduce the hazard of causative bacteria or the harmful aerosols produced during bioexperiment to the operator and environment

2.7

aerosols

the relatively-stable disperse system generally formed by 0.001μm ~ 100μm solid or liquid tiny particles suspending in the gas medium

2.8

biosafety laboratory

the causative bacteria laboratory that meets the biosafety requirements through protective barrier and control measures

2.9

laboratory containment area

the physical zone of the laboratory; in the zone, biohazard risk is relatively large and the plane design of the laboratory, airtightness of enclosing structure, airflow as well as personnel entrance, individual protection and the like shall be controlled

2.10

non-contamination zone

the area with relative small biohazard or the area other than the containment area in biosafety laboratory

2.11

core area

the primary area for carrying out laboratory activities in biosafety laboratory; which generally refers to the room where biosafety cabinet or animal feeding room and operation room exist

2.12

enhanced biosafety level 2 laboratory

the laboratory in which laboratory biosafety protection requirements are enhanced through mechanical ventilation system and other measures based on ordinary biosafety level 2 laboratory

2.13

accident

the unexpected conditions leading to personal and animal infection, injury and death or facility/equipment damage and other losses

2.14

incident

the condition causing or possibly causing accident

2.15

high efficiency particulate air filter

the air filter whose filtration efficiency is greater than 99.97% under specified conditions and generally taking 0.3μm particulates as the test objects

2.16

air lock

the airtight room possessed of mechanical air supply and exhaust system, integral disinfection and sterilization conditions, chemical spraying (if applicable) and monitorable pressure; its doors shall be possessed of interlock function and cannot remain in open state at the same time

3 Classification of Causative Bacteria Hazard Degree

Causative bacteria are divided into four categories according to their infectivity and the hazard degree to individual or group after infection:

a) Category I causative bacteria: the bacteria that will cause very severe human or animal diseases, as well as the bacteria that have not been discovered in China or have already been declared eliminated.

b) Category II causative bacteria: the bacteria that will cause severe human or animal diseases, and are easy to be directly or indirectly transmitted between people, animal and people, as well as animals.

c) Category III causative bacteria: the bacteria that will cause human or animal diseases, but generally will not cause severe hazard to people, animals or environment, with limited transmission risk; after laboratory infection, they will rarely lead to severe disease and there are effective treatment and prevention measures.

d) Category IV causative bacteria: the bacteria that will not cause human or animal diseases normally.

Note 1: Category I and Category II causative bacteria are collectively referred to highly pathogenic causative bacteria.

4 Rating and Classification of Laboratory Biosafety Protection Level

4.1 Rating

4.1.1 Laboratories are divided into Biosafety Level 1 (BSL-1), Biosafety Level 2 (BSL-2), Biosafety Level 3 (BSL-3) and Biosafety Level 4 (BSL-4) according to the biosafety protection level of laboratory for causative bacteria and national standards for laboratory biosafety.

4.1.2 Biosafety level 1 laboratory is applicable to operate the bacteria that will not cause human or animal diseases normally.

4.1.3 Biosafety level 2 laboratory is applicable to the bacteria that will cause human or animal diseases, but generally will not cause severe hazard to people, animals or environment, with limited transmission risk; after laboratory infection, they will rarely lead to severe disease and there are effective treatment and prevention measures. BSL-2 laboratories are divided into ordinary BSL-2 laboratory and enhanced BSL-2 laboratory according to whether the laboratory is provided with mechanical ventilation system.

4.1.4 Biosafety level 3 laboratory is applicable to operate the bacteria that will cause severe human or animal diseases, and are easy to be directly or indirectly transmitted between people, animal and people, as well as animals.

4.1.5 Biosafety level 4 laboratory is applicable to operate the bacteria that will cause very severe human or animal diseases, as well as the bacteria that have not been discovered in China or have already been declared eliminated.

4.2 Classification

4.2.1 BSL-1, BSL-2, BSL-3 and BSL-4 represent the corresponding biosafety protection level of the laboratories only engaged in external operation.

4.2.2 ABSL-1 (Animal Biosafety Level, ABSL-1), ABSL-2, ABSL-3 and ABSL-4 represent the corresponding biosafety protection level of the laboratories engaged in living animal operation.

4.2.3 Animal biosafety laboratories are divided into the laboratory engaged in vertebrate experiment and that engaged in invertebrate experiment.

4.2.4 According to the difference of experiment, adopted PPE and basic isolation facilities, laboratories are divided into:

a) laboratory where the pathogenic biological agents that are generally regarded as non-air-transmitted can be operated;

b) laboratory where safety isolation devices (such as level 2 biosafety cabinet) can be effectively used to operate routine-quantity air-transmitted pathogenic biological agents;

c) laboratory where safety isolation devices (such as level 2 biosafety cabinet) can’t be effectively used to operate routine-quantity air-transmitted pathogenic biological agents;

d) laboratory where positive pressure clothing with life support system can be used to operate routine-quantity air-transmitted pathogenic biological agents;

e) laboratory where the equipment with level 3 biosafety cabinet can be used to operate routine-quantity air-transmitted pathogenic biological agents.

5 Risk Assessment and Risk Control

5.1 General

Risk assessment and risk control systems shall be established and maintained in the laboratory to determine specific requirements for laboratory to continually carry out risk identification, risk assessment and risk control (see Annex A).

5.2 Risk identification

Where pathogenic biological agents are involved in experiment, risk factors including but not limited to those described in a) to j) of 5.2 shall be identified:

a) The known or unknown characteristics of pathogenic biological agents involved in experiment, for example:

1) hazard degree classification;

2) biological characteristics;

3) route of transmission and transmissibility;

4) infectivity and pathogenicity: susceptibility, host range, amount essential for a pathogen, incubation period, clinical symptom, course of disease, prognosis, etc.;

5) interaction with other lives and the environment, relevant experimental data and epidemiological data;

6) stability in environment;

7) preventive, therapeutic and diagnostic measures, including vaccine, therapeutic drugs and the diagnostic reagent used for infection testing.

b) Experiment involving pathogenic biological agents, for example:

1) collection, transfer, preservation and destroy of microorganism strain and infectious substance;

2) separation, cultivation, evaluation, preparation and the like;

3) operation easy to produce aerosols, e.g. centrifugation, grinding, oscillation, homogenate, ultrasound, inoculation, freeze drying;

4) use of sharp instruments such as syringe needle, anatomy instrument, glassware, etc.;

c) Where Genetically Modified Organisms (GMOs) are involved in experiment, the hazard caused by recombinant shall be considered.

d) Animal feeding and experiment involving pathogenic biological agents:

1) scratches or bites;

2) animal dander and aerosols produced from breathing;

3) anatomy, sampling, testing, etc.;

4) treatment of excrement, secretion, tissue/organ/carcass, padding and waste, etc.;

5) possible failure of animal cage, instrument and control system, etc.

e) Risk in infectious waste treatment:

1) waste container, packaging and identification;

2) collection, disinfection, storage and transportation, etc.;

3) leakage of infectious waste;

4) reliability of sterilization;

5) risk of possible contacting with infectious waste by people outside of facilities.

f) Risks of experiment safety management, including, but not limited to:

1) management measures and technical measures to eliminate, reduce or control risk as well as residual or new risk after taking measures;

2) operating experience and risk control measures, including possible risks of management procedure, operation specification, maintenance specification and the like relevant to facilities and equipment;

3) new risk which may be caused by implementing emergency measures.

g) Relevant personnel in experiment involving pathogenic biological agents:

1) professional and biosafety knowledge and operation skill;

2) perception for risk;

3) psychological quality;

4) professional and biosafety training condition;

5) disposal capability for incident/accident;

6) health status;

7) health monitoring, medical security and medical rescue;

8) safety management and provided protective measures for experimenter from other organizations.

h) Laboratory facility and equipment:

1) biosafety cabinet, centrifuge, shaking table and incubator, etc.;

2) waste and wastewater disposal facility and equipment;

3) personal protective equipment;

If applicable, including:

1) airtightness, pressure, temperature and flow control of the containment area;

2) interlocking, air-tight door and access control system;

3) those such as ventilation and air conditioning system as well as water, electrical and gas system associated with containment area;

4) safety monitoring and alarm system;

5) animal feeding and operating facility/equipment;

6) facility/equipment for preservation of microorganism strain and sample;

7) radiation protection device;

8) life support system, positive-pressure protective clothing, chemical shower, etc.;

i) Laboratory biological security system and security measures, mainly for identifying the risk of preserved or used pathogenic biological agents being stolen, misused and maliciously released.

j) Reason analysis for occurred laboratory infection.

5.3 Risk assessment

5.3.1 Risk assessment shall be based on national laws and regulations, standards and codes as well as the guideline, data and the like issued by the authority. The identified risks shall be analyzed to form risk assessment report.

5.3.2 Risk assessment shall be carried out by experienced professional personnel in different fields (not limited to the personnel in the organization).

5.3.3 Risk assessment shall be carried out by the laboratory based on 5.2 and in combination with but not limited to the following conditions:

a) where the biological characteristics or prevention and control strategies of pathogen are changed;

b) new experiments are carried out or experiments are changed (including facilities, equipment, personal, range of activity, regulation, etc.);

c) the operation quantity exceeds routine quantity or specific activity is engaged;

d) the laboratory or similar laboratory has infection incident or infection accident;

e) where relevant policies, laws and regulations, standards and the like are changed.

Foreword i
1 Scope
2 Terms and Definitions
3 Classification of Causative Bacteria Hazard Degree
4 Rating and Classification of Laboratory Biosafety Protection Level
5 Risk Assessment and Risk Control
6 Laboratory Facilities and Equipment Requirements
7 Management Requirements for Laboratory Biosafety
Annex A (Informative) Risk Assessment Table for Causative Bacteria Experiment
Annex B (Informative) Approval Table for Causative Bacteria Experiment
Annex C (Informative) On-site Inspection of Biosafety Isolation Equipment
Annex D (Informative) Monitoring of Effect of Pressure Steam Sterilizer
Bibliography

Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.