Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
buildings section cobalt content ― flame p-tert-butylcyclohexyl acetate
WS 76-2020 in English

WS 76-2020 in English

VALID

Specification for testing of quality control in medical X-ray diagnostic equipment

  • Issued on:2020-10-26
  • Implemented on:2021-05-01
  • File Format:PDF
  • Delivery:Via email within 10 business days
Price(USD): $1,050.00
$1,019.00
Standard No: WS 76-2020
Document status: VALID
Title in English: Specification for testing of quality control in medical X-ray diagnostic equipment
Title in Chinese: 医用X射线诊断设备质量控制检测规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 10 business days
Issued on: 2020-10-26
Implemented on: 2021-05-01
Superseding: WS 518-2017 Specification for testing of quality control in screen film mammography systems
WS 520-2017 Specification for testing of quality control in computed radiography (CR)
WS 521-2017 Specification for testing of quality control in medical digital radiography(DR)systems
WS 522-2017 Specification for testing of quality control in digital mammography systems
WS 530-2017 Specification for testing of quality control in computed radiography systems for mammography
WS 581-2017 Specification for testing of quality control in dental X-ray equipment
WS 76-2017 Specification for testing of quality control in medical X-ray diagnostic equipment
Professional Classification: WS-Hygiene
Related Topics: x-ray
Ray standard
x-ray standard
Substance testing equipment
X-ray detection
X-ray detection equipment
Testing specification
medical consultation box
In measurement control x
Rapid Diagnostic Test Equipment
High quality x-ray inspection
X-ray inspection equipment
diagnostic equipment
equipment quality
Second-hand x testing equipment
xInspection equipment
X-ray measuring equipment
Molecular Diagnostic Tests
Quality testing equipment
X-ray equipment
Rays and Matter x
x-ray
diagnostic equipment
dosimeter detector
Testing equipment quality
x-ray medicine
3D x-ray inspection
X-ray quality detector
Inspection and diagnosis equipment
Inspection and diagnosis equipment
equipment quality
X-ray quality inspection equipment
Energy detection equipment
High Energy X-ray Inspection
Testing equipment
x-ray medicine
X-ray diagnostic equipment
Rays
Industry quality of measurement and control equipment
Controller factory quality inspection specifications


Introduction

Overview of the core content of the standard

WS 76-2020 integrates 7 old standards, adds new DSA equipment testing requirements, and revises technical indicators such as low-contrast resolution of perspective. The standard applies to the quality control of X-ray photography, perspective, dental and breast equipment, and clarifies the three-level testing system of acceptance testing, status testing and stability testing.


Key test items and technical indicators

Equipment type Core test items Acceptance criteria Status test cycle
Fluoroscopic equipment Incident body surface air kerma rate ≤25.0 mGy/min 1 year
DR equipment Detector dose indication (DDI) ±20% deviation 1 year
Breast equipment Half-value layer (HVL) Mo/Mo target: 0.30-0.40mmAl 1 year

Implementation points and case analysis

Case: DR equipment signal transmission characteristics detection

When a hospital used the Siemens Mobilett Mira Max DR equipment, it was found that the image grayscale was abnormal. According to WS 76-2020 requirements:

  1. Set 70kV/1mmCu filtration and take 5 dose exposures in the range of 1-30μGy
  2. Measure the average pixel value of the ROI in the center of the preprocessed image
  3. Linear fitting R² must be ≥0.98 (acceptance) or ≥0.95 (status detection)

The detection found that R²=0.92, indicating a nonlinear response of the detector, which was restored to 0.99 after calibration.


Standard Evolution and Innovation

Main changes compared with the 2017 version:

  • Added DSA dynamic range detection: Requires 0.4mm vascular simulation components to be visible in full grayscale
  • Strengthen low contrast requirements: The contrast threshold for acceptance inspection of fluoroscopic equipment is reduced from 4% to 2%
  • Special for digital equipment: Added DR afterimage detection (pixel value error ≤ 5%)

Sample only — not a preview of WS 76-2020
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • WS/T 118-1999 in English

    WS/T 118-1999 in English

    Classification and codes of medical apparatuses instruments and equipment (commodities supplies) for the national health system

    1999-01-21