Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)

x-ray medicine

x-ray medicine, Total:462 items.

The international standard classification for "x-ray medicine" includes: Radiographic films , Radiation measurements , Radiographic equipment , Occupational safety. Industrial hygiene , Radiation protection , Medical Sciences and health care facilities in general , Dental materials , Protection against crime , Other standards related to optics and optical measurements .

The Chinese standard classification for "x-ray medicine" includes: Photosensitive material , Ionizating Radiation Measurement , Medical radiographic equipment , Radiological sanitation protection , Medical science , Technical management , Stomatologic device, equipment and material , Crime judging technology , Electron optics and other physical optics instrument .


Professional Standard - Chemical Industry

Professional Standard - Light Industry

National Metrological Verification Regulations of the People's Republic of China

  • JJG 744-2004 Verification Regulation of Medical diagnostic X-ray Radiation Source
  • JJG 1145-2017 Medical X-ray Radiation Sources for Mammographic Equipment
  • JJG 1101-2014 Medical Diagnostic X-ray Source for Dental Panorama
  • JJG 1078-2012 X-ray Radiation Sources for Medical Computed Radiography System and Digital Radiography System
  • JJG 744-1997 Verification Regulation of Medical Diagnostic X-Ray Radiation Source

Professional Standard - Medicine

  • YY/T 1307--2016 Detector for medical breast digital X-ray photography
  • YY/T 0609-2007 General specifications of medical diagnostic X-ray tube assemblies
  • YY/T 0722-2016/tec 61676:2009 Medical electrical equipment Dosimetric instruments for non-accessible measurement of X-ray tube voltage in diagnostic radiology
  • YY/T 0093-2013 Medical diagnostic X-ray image intensifier
  • YY/T 0347-2009 Particular specifications for mini medical diagnostic X-ray equipment
  • YY/T 0093-2004 Medical diagnostic X-ray image intensifier
  • YY 0201-1995 100mA medical diagnostic X-ray machine
  • YY/T 0106-2004 General specifications for medical diagnostic X-ray equipuent
  • YY/T 0347-2002 General specifications for medical diagnostic X-ray microequipment
  • YY/T 0197.5-2007 X-ray tube for medical diagnosis XD51-20、40/100 and XD51-20、40/125 rotating anode X-ray tube
  • YY/T 0481-2016 Medical diagnostic X-ray equipment—Radiation conditions for use in the determination of characteristics
  • YY/T 0934-2014 Dynamic digital medical X-ray image detectors
  • YY 0197.1-1995 Detail specification for medical X-ray tubes - XD1-3/100X-ray tubes
  • YY/Y 0093-2004 Medical diagnostic X-ray image intensifier
  • YY 0200-1995 50mA medical diagnostic X-ray machine
  • YY 0007-1990 200MA medical diagnostic X-ray machine
  • YY/T 0197.3-2007 Medical diagnostic X-ray tube XD3-3.5/100 fixed anode X-ray tube
  • YY/T 0197.4-2007 X-ray tube for medical diagnosis XD4-2、9/100 stationary anode X-ray tube
  • YY/T 0291-1997 Environmental requirements and test methods for medical X-ray equipment
  • YY/T 0128-2023 Protective devices against diagnostic medical X-radiation--Device and tool
  • YY/T 0892-2013 Methods for the measurement of leakage radiation of medical diagnostic X-ray tube assemblies
  • YY 0197.5-1995 Detail specification for medical X-ray tubes - XD51-20,40/100 and XD51-20,40/125 rotation anode X-ray tubes
  • YY 0128-1993 Medical x-ray protection device and appliance
  • YY/T 0481-2004 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • YY/T 0106-2008 General specifications for medical diagnostic X-ray equipment
  • YY/T 1307-2016 Medical digital X-ray image detector used in mammography
  • YY 0199-1995 30mA medical diagnostic X-ray machine
  • YY 0008-1990 300MA medical diagnostic X-ray machine
  • YY 0009-1990 500MA medical diagnostic X-ray machine
  • YY 0197.3-1995 Detail specification for medical X-ray tubes - XD3-3.5/100X-ray tubes
  • YY/T 0128-2004 Protective devices against diagnostic medical X-radiation—Device and tool
  • YY/T 0063-2007 Medical electrical equipment—X-ray tube assemblies for medical diagnosis—Characteristics of focal spots
  • YY/T 1944-2024 Special technical requirements for medical X-ray high voltage generators
  • YY/T 0317-2007 General specifications for medical therapeutic X-ray equipment
  • YY/T 0739-2009 Particular specifications for wall stand of medical X-ray equipment
  • YY/T 0479-2004 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • YY/T 0094-2013 X-ray fluorescent screens for medical diagnosis
  • YY/T 0063-2000 X-ray tube assemblies for medical diagnosis-Characteristics of focal spots
  • YY 91029-1999 400 mA X-ray equipment for medical diagnosis
  • YY/T 0722-2009 Medical electrical equipment - Dosimetric instrument used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • YY/T 1307-2024 Detectors for medical mammography digital X-ray
  • YY/T 0291-2016 Environmental requirements and test methods for medical X-ray equipment
  • YY/T 0202-2004 Medical diagnostic X-ray device for tomography
  • YY 0317-2000 General specifications for medical therapeutic X-ray equipment
  • YY/T 0291-2007 Environmental requirements and test methods for medical x-ray equipment
  • YY/T 0064-2016/IEC 60613:2010 Electrical and load characteristics of medical diagnostic X-ray tube components
  • YY 0007~0009-1990 200mA, 300mA, 500mA medical diagnostic X-ray machine
  • YY 0197.2-1995 Detail specification for medical X-ray tubes - XD2-1/85X-ray tubes
  • YY 0197.4-1995 Detail specification for medical X-ray tubes - XD4-2 and 9/100X-ray tubes
  • YY/T 1099-2007 Packaging,transportation and storage for medical X-ray equipment
  • YY/T 0130-1993 Standard system table of medical X-ray equipment and appliances
  • YY/T 0197.1-2007 X-ray tube for medical diagnosis—XD1-3/100 stationary anode X-ray tube
  • YY/T 0197.3-2007 X-ray tube for medical diagnosis XD3-3.5/100 stationary anode X-ary tube
  • YY/T 0740-2022 Particular specifications for medical X-ray angiography equipment
  • YY/T 0740-2009 Particular specifications for medical X-ray angiography equipment
  • YY/T 0094-2004 X-ray fluorescent screens for medical diagnosis
  • YY/T 0481-2016/IEC 61267:2005 Radiation conditions for the determination of characteristics of medical diagnostic X-ray equipment
  • YY/T 0197.2-2007 X-ray tube for medical diagnosis—XD2-1/85 stationary anode X-ray tube
  • YY/T 0738-2009 Particular specifications for cardiovascular table
  • YY/T 0737-2009 Particular specifications for medical X-ray radiographic table
  • YY 0198-1995 10mA medical diagnostic X-ray machine
  • YY/T 0722-2016/tec 61676-2009 Medical electrical equipment Dosimetry instruments for non-intrusive measurement of X-ray tube voltage in diagnostic radiology

工业和信息化部

Occupational Health Standard of the People's Republic of China

  • GBZ 264-2015 Radiological protection requirements for medical X-ray diagnostic system installed on vehicle
  • GBZ(卫生) 130-2013 Requirements for radiological protection in medical X-ray diagnosis
  • GBZ(卫生) 264-2015 Radiological protection requirements for medical X-ray diagnostic systeminstalled on vehicle
  • GBZ/T 180-2006 Radiation shielding specification for room of medical X-ray CT scanner
  • GBZ 130-2013 Requirements for radiological protection in medical X-ray diagnosis
  • GBZ/T 184-2006 Standards of protective glass plate against diagnostic medical X-ray
  • GBZ(卫生) 131-2017 Requirements for radiological protection in medical X-ray therapy

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

  • GBZ 131-2017 Requirements for radiological protection in medical X-ray therapy
  • GB 8279-2001 Requirements for radiological protection in medical X-ray diagnosis
  • GB 9706.11-1997 Medical electrical equipment-Part 2: Particular requirements for the safety of X-ray source assemblies and X-ray tube assemblies for medical diagnosis
  • GB/T 10149-1988 Terminology and symbol for medical X-ray equipment
  • GB/T 13797-2009 General specifications for medical X-ray tube
  • GB 11756-1989 General specifications of medical diagnostic X-ray tube assemblies
  • GB 18464-2001 Requirements for radiological protectionin medical X-ray therapy
  • GB 11755.2-1989 Medical diagnostic X-ray machine tube current test method
  • GB/T 13797-2023 General specifications for X-ray tube
  • GB/T 13797-1992 Blank detail specification of X-ray tubes for medical practice
  • GB/T 11757-1989 Methods for the measurement of exposure time of medical diagnostic X-ray equipment
  • GB/T 11755.1-1989 Methods for the measuring of tube voltage of medical diagnostic X-ray equipment
  • GB 11757-1989 Medical diagnostic X-ray machine exposure time test method
  • GB 10149-1988 Terms and symbols for medical X-ray equipment
  • GB 16348-2010 Radiological protection standards for the examinee in medical X-ray diagnosis
  • GB/T 11755.2-1989 Methods for the measuring of tube current of medical diagnostic X-ray equipment

Professional Standard - Hygiene

  • WS/T 190-1999 Specifications for radiological protection monitoring in medical X-ray diagnosis
  • WS/T 76-1996 General aspects for quality assurance in medical X-ray image of diagnosis
  • WS/T 75-1996 Guide for reasonable application of medical X-ray diagnosis
  • WS/T 389-2012 Medical X-ray examination procedure

Group Standards of the People's Republic of China

National Metrological Technical Specifications of the People's Republic of China

  • JJF 1268-2010 Calibration Specification for Medical Diagnostical X-ray Radiation Source for Computer Tomography (CT)Phantom

Henan Provincial Standard of the People's Republic of China

  • DB41/T 2568-2023 Medical X-ray Diagnostic Radiation Environment Monitoring Specifications

Professional Standard - Electron

  • SJ/T 11095-1996 General specification for medical X-ray television equipment
  • SJ/T 11096-1996 Measuring methods for medical X-ray television equipments

国家食品药品监督管理局

  • YY/T 0609-2018 General specifications of medical diagnostic X-ray tube assemblies
  • YY/T 0722-2016 Medical electrical equipment—Dosimetric instrument used for non-invasive measurement of X-ray tube voltage in diagnostic radiology

卫生健康委员会

  • WS 76-2020 Specification for testing of quality control in medical X-ray diagnostic equipment

Tianjin Provincial Standard of the People's Republic of China

  • DB12/T 802-2018 Radiological protection requirements for operation next to medical mobile X-ray machine tools

国家药监局

  • YY/T 0106-2021 General specifications for medical diagnostic X-ray equipment
  • YY/T 1708.6-2021 Basic requirements of communication and conformance for medical X-ray image equipment——Part 6:X-ray unit for oral cavity
  • YY/T 1708.5-2021 Basic requirements of communication and conformance for medical X-ray image equipment——Part 5:Mammography
  • YY/T 1646-2019 Dentistry—Test method for determining radio-opacity of materials
  • YY/T 0934-2022 Dynamic digital medical X-ray image detectors

Professional Standard - Public Safety Standards

  • GA/T 2079-2023 Forensic sciences-Examination methods for minerals-X-ray diffractometry

国家医药管理局

  • YY/T 0063-1991 Medical diagnostic X-ray tube assembly focus characteristics

中华人民共和国国家卫生和计划生育委员会

  • GBZ 130-2002 Health Protection Standards for Medical X-ray Diagnosis (Abolished)

Professional Standard - Machinery

NEMA - National Electrical Manufacturers Association

  • NEMA XR 12-1988 Electrical and Thermal Characteristics for X-Ray Tubes and X-Ray Tube Housings Used in Medical Diagnosis

CZ-CSN

Malaysia Standards

  • MS 838-1985 Radiation Protection Code of Practice (Medical X-ray Diagnosis)

International Electrotechnical Commission (IEC)

  • IEC 60806:2022 Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis
  • IEC 60407:1973 Radiation protection in medical X-ray equipment 10 kV to 400 kV
  • IEC 60406:1997 Cassettes for medical X-ray diagnosis - Radiographic cassettes and mammographic cassettes
  • IEC 61676:2002+AMD1:2008 CSV Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • IEC 60336:1993 X-ray tubes assemblies for medical diagnosis; characteristics of focal spots
  • IEC 60601-2-28:1993 Medical electrical equipment; part 2: particular requirements for the safety of X-ray source assemblies and X-ray tube assemblies for medical diagnosis
  • IEC 61267:2005 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characetristics
  • IEC 60336:2005 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
  • IEC 61267:1994 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • IEC 61676:2023 RLV Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • IEC 61676:2023 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • IEC 60613:2010 Electrical and loading characteristics of X-ray tube assemblies for medical diagnosis

British Standards Institution (BSI)

  • BS EN 60406:1997 Specification for radiographic cassettes and mammographic cassettes used for medical X-ray diagnosis
  • BS EN IEC 60806:2022 Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis
  • 18/30372517 DC BS EN 60336. Medical electrical equipment. X-ray tube assemblies for medical diagnosis. Characteristics of focal spots
  • BS EN 62220-1-2:2007 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Determination of the detective quantum efficiency - Detectors used in mammography
  • BS 6058:1990 Method of specifying and verifying the characteristics of rotating anode X-ray tubes and X-ray tube assemblies used in medical diagnosis
  • BS 6058:1989 Method of specifying and verifying the characteristics of rotating anode X-ray tubes and X-ray tube assemblies used in medical diagnosis
  • BS EN IEC 60336:2021(2022) Medical electrical equipment — X - ray tube assemblies for medical diagnosis — Focal spot dimensions and related characteristics
  • 21/30425846 DC BS EN IEC 60806. Determination of the maximum symmetrical radiation field of X-ray tube assemblies or X-ray source assemblies for medical diagnosis
  • BS EN 61223-3-1:1999 Evaluation and routine testing in medical imaging departments. Acceptance tests. Imaging performance of X-ray equipment for radiographic and radiscopic systems
  • BS 3043:1973 Specification for storage envelopes for processed X-ray films for medical radiography
  • BS EN 61267:2006 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • BS EN 61331-2:2002 Protective devices against diagnostic medical X-radiation - Protective glass plates
  • BS ISO 20289:2018 Surface chemical analysis. Total reflection X-ray fluorescence analysis of water
  • BS ISO 16129:2012 Surface chemical analysis. X-ray photoelectron spectroscopy. Procedures for assessing the day-to-day performance of an X-ray photoelectron spectrometer
  • BS EN 60526:2004 High-voltage cable plug and socket connections for medical X-ray equipment
  • BS EN 60526:2005 High-voltage cable plug and socket connections for medical X-ray equipment
  • BS 2606:1955 Specification for X-ray protective gloves for medical diagnostic purposes up to 150 kV peak
  • BS EN 60336:2005 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots

SCC

  • CEI EN IEC 60806:2023 Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis
  • DANSK DS/EN IEC 60806:2023 Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis
  • BS EN 60336:1995 X-ray tube assemblies for medical diagnosis. Characteristics of focal spots
  • BS 6058:1981 Method of specifying and verifying the characteristics of rotating anode X-ray tubes and X-ray tube assemblies used in medical diagnosis
  • IEC 60637:1979 Marking of and accompanying documents for X-ray tubes and X-ray tube assemblies for medical use
  • BS 6059:1981 Specification for essential data to be supplied with X-ray tubes and X-ray tube assemblies for medical use
  • CEI EN 60336:2006 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
  • AENOR UNE-EN 60336:2006 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
  • VDI/VDE 5575 BLATT 7-2019 X-ray optical systems - Refractive X-ray lenses
  • CEI EN 60806:2005 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • AENOR UNE-EN 60806:2005 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • CEI EN 60406:1998 Cassettes for medical X-ray diagnosis - Radiographic cassettes and mammographic cassettes
  • DANSK DS/EN 60806:2004 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • DANSK DS/EN 60406:1997 Cassettes for medical X-ray diagnosis - Radiographic cassettes and mammographic cassettes
  • NEMA XR 10-1986(R2003) Measurement of the Maximum Symmetrical Radiation Field from a Rotating Anode X-Ray Tube Used for Medical Diagnosis
  • BS 7817-2:1995 Protective devices against diagnostic medical X-radiation-Specification for protective glass plates
  • VDI/VDE 5575 BLATT 10-2019 X-ray optical systems - diffraction gratings
  • BS 3491:1962 Specification for sizes of medical X-ray film
  • IEC 60613:1978 Electrical, thermal and loading characteristics of rotating anode X-ray tubes for medical diagnosis
  • VDI/VDE 5575 BLATT 4:2018 X-ray optical systems — X-ray mirrors and X-ray mirror systems — Total reflection and multilayer mirrors
  • VDI/VDE 5575 BLATT 1:2018 X-ray optical systems — terms
  • VDI/VDE 5575 BLATT 6:2018 X-ray optical systems — reflection zone plates
  • VDI/VDE 5575 BLATT 5:2018 X-ray optical systems — transmission zone plates
  • DIN EN IEC 60806:2023 Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis (IEC 60806:2022); German version EN IEC 60806:2023
  • CAN/CSA-C22.2 No.601.2.28-1994(R2007) Medical electrical equipment - Part 2: Particular requirements for the safety of X-ray source assemblies and X-ray tube assemblies for medical diagnosis
  • VDI/VDE 5575 BLATT 2-2019 X-ray optical systems - measurement methods; Measurement setup and methods for evaluating x-ray optical systems
  • IEC 60336:1982 Characteristics of focal spots in diagnostic X-ray tube assemblies for medical use
  • BS EN 61267:1995 Radiation conditions for use in the determination of characteristics for medical diagnostic X-ray equipment
  • CEI EN 61267:2006 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • DANSK DS/EN 61267:2006 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • JIS Z 4716:2018 Measurement methods of leakage X-ray from X-ray examination rooms
  • DIN EN IEC 60806 E:2022 Draft Document - Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis (IEC/CDV 60806:2021); German and English version prEN IEC 60806:2021
  • NEMA XR 19-1993(R1999) Electrical, Thermal and Loading Characteristics of X-Ray Tubes Used for Medical Diagnosis
  • DIN 6868-150 E:2020 Draft Document - Image quality assurance in diagnostic X-ray departments - Part 150: Acceptance test of medical radiographic and fluoroscopic X-ray equipment
  • CEI EN IEC 61676:2023 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • DANSK DS/EN IEC 61676:2023 Medical electrical equipment – Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • DANSK DS/EN 61676:2003 Medical electrical equipment – Dosimetric instuments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • CEI EN 61223-3-1:2001 Evaluation and routine testing in medical imaging departments - Part 3: Acceptance tests - Imaging performance of X-ray equipment for radiographic and radioscopic systems
  • CEI EN 61676/A1:2004 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • AENOR UNE-EN 61676/A1:2003 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • AENOR UNE-EN 61676:2003 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • CEI EN 61676:2004 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • DIN 6812:2021 Medical X-ray equipment up to 300 kV - Rules of construction for structural radiation protection
  • DIN 6868-4 E:2019 Draft Document - Image quality assurance in diagnostic X-ray departments - Part 4: Constancy testing of medical X-ray equipment for fluoroscopy
  • AENOR UNE-EN 61267:2006 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics (IEC 61267:2005)
  • DANSK DS/EN 60336:2005 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
  • BS IEC 61223-2-10:2000 Evaluation and routine testing in medical imaging departments. Constancy tests-X-ray equipment for mammography
  • BS 6530:1984 Methods for determining the characteristics of focal spots in diagnostic X-ray tube assemblies for medical use
  • CEI EN 60526:2005 High-voltage cable plug and socket connections for medical X-ray equipment
  • CEI EN IEC 61223-3-8:2024 Evaluation and routine testing in medical imaging departments – Part 3-8: Acceptance and constancy tests - Imaging performance of X-ray equipment for radiography and radioscopy

German Institute for Standardization

  • DIN EN IEC 60806:2022-09 Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis (IEC/CDV 60806:2021); German and English version prEN IEC 60806:2021 / Note: Date of issue 2022-08-12*Intended as replac...
  • DIN EN 60336:2006-09 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots (IEC 60336:2005); German version EN 60336:2005 / Note: To be replaced by DIN EN 60336 (2020-04).
  • DIN 6868-150:2013 Image quality assurance in diagnostic X-ray departments - Part 150: RöV acceptance test of medical radiographic and fluoroscopic X-ray equipment
  • DIN 6814-6:2009-05 Terms in the field of radiological technique - Part 6: Diagnostic use of X-radiation in medicine
  • DIN EN 60806:2006-04 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis (IEC 60806:1984); German version EN 60806:2004 / Note: To be replaced by DIN EN IEC 60806 (2022-09).
  • DIN EN IEC 60806:2023-12 Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis (IEC 60806:2022); German version EN IEC 60806:2023
  • DIN EN 61267:2009 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics (IEC 61267:2005); German version EN 612167:2006
  • DIN EN IEC 60806:2022 Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis (IEC/CDV 60806:2021); German and English version prEN IEC 60806:2021
  • DIN 6868-150:2022-01 Image quality assurance in diagnostic X-ray departments - Part 150: Acceptance test of medical radiographic and fluoroscopic X-ray equipment
  • DIN 6868-150 E:2012-02 Image quality assurance in diagnostic X-ray departments - Part 150: Acceptance test of medical radiographic and fluoroscopic X-ray equipment
  • DIN 6868-150:2022 Image quality assurance in diagnostic X-ray departments - Part 150: Acceptance test of medical radiographic and fluoroscopic X-ray equipment
  • DIN 6868-150 E:2020-12 Image quality assurance in diagnostic X-ray departments - Part 150: Acceptance test of medical radiographic and fluoroscopic X-ray equipment
  • DIN EN 61267:2009-01 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics (IEC 61267:2005); German version EN 612167:2006
  • DIN EN 61267:1997 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • DIN 6862-1:1992 Identification and characterisation of radiological images in medical diagnosis; direct and indirect radiography
  • DIN 6812:2021-06 Medical X-ray equipment up to 300 kV - Rules of construction for structural radiation protection
  • DIN EN 61676:2010-05 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology (IEC 61676:2002+A1:2008); German version EN 61676:2002+A1:2009 / Note: To be replaced by DIN EN IEC 61676 (2022-05).
  • DIN EN IEC 61676:2022-05 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology (IEC/CDV 61676:2021); German and English version prEN IEC 61676:2022 / Note: Date of issue 2022-03-25*Intended as repl...
  • DIN 6836:1963 X-ray tubes and single tank X-ray generators; holders for X-ray application tables and stands, dimensions for assembling
  • DIN 13273-7:2020-12 Catheter for medical use - Part 7: Determination of the x-ray attenuation of catheters; requirements and testing
  • DIN 6812:2002 Medical X-ray equipment up to 300 kV - Radiation protection rules for installation
  • DIN EN 61676:2010 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology (IEC 61676:2002+A1:2008); German version EN 61676:2002+A1:2009
  • DIN 6868-4:2007 Image quality assurance in diagnostic X-ray departments - Part 4: Constancy testing of medical X-ray equipment for fluoroscopy
  • DIN 6812 E:2000-04 Medical X-ray equipment up to 300 kV - Rules of construction for structural radiation protection
  • DIN 6812:2013 Medical X-ray equipment up to 300 kV - Rules of construction for structural radiation protection
  • DIN 6812 E:2011-10 Medical X-ray equipment up to 300 kV - Rules of construction for structural radiation protection
  • DIN 6812:2010 Medical X-ray equipment up to 300 kV - Rules of construction for structural radiation protection
  • DIN EN 60806:2006 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis (IEC 60806:1984); German version EN 60806:2004
  • DIN 6812 E:2020-08 Medical X-ray equipment up to 300 kV - Rules of construction for structural radiation protection
  • DIN 6812 E:2008-08 Medical X-ray equipment up to 300 kV - Rules of construction for structural radiation protection
  • DIN EN 60613:1992 Electrical and loading characteristics of X ray tube assemblies for medical diagnosis

Association Francaise de Normalisation

  • NF EN 60406:2015 Cassettes for medical radiography - X-ray cassettes and mammography cassettes
  • NF S92-502:2013 Laboratory of medical biology - Anthroporadiometric measurements - Lungs - Measurement of X-ray and gamma-ray emissions of energy less than 200 keV
  • NF C74-111:1985 Electromedical equipment. Radiology equipment. X radiation equipment. Radiodiagnostic X-ray tube assemblies. Construction and tests. Requirements.
  • NF S92-502:2006 Medical biology analysis laboratory - Anthroporadiametric - Lungs countings - Measurements of low energy X and gamma emitters (less than 200 keV).
  • NF EN 61331-2:2015 Radiological protection devices against X-rays for medical diagnosis - Part 2: translucent radiological protection plates
  • NF C74-118:1993 Medical electrical equipment. Part 2 : particular requirements for the safety of X-ray source assemblies and X-ray tube assemblies for medical diagnosis.
  • NF EN 61267:2006 X-ray medical diagnostic equipment - Radiation conditions for use in determining characteristics
  • NF C74-106:1984 Radiological equipment. Radiographic intensifying screens for medical use. Dimensions.
  • NF C74-230/A1*NF EN 61676/A1:2009 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • NF C74-114*NF EN 60613:2010 Electrical and loading characteristics of X -ray tube assemblies for medical diagnosis.
  • NF C74-120*NF EN 61267:2006 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • NF EN 61223-3-2:2008 Evaluation and routine testing in medical imaging departments - Part 3-2: acceptance testing - Imaging performance of X-ray mammography machines
  • NF C15-161:1990 Installations for the generation and application of X-rays - Particular requirement for medical veterinary (excluding dental) diagnostic installations.
  • NF EN 61676/A1:2009 Electromedical devices - Dosimetry instruments for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • NF C74-126*NF EN 60806:2004 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • NF C74-166*NF EN 60526:2005 High-voltage cable plug and socket connections for medical X-ray equipment
  • NF EN IEC 61676:2023 Electromedical devices - Dosimetry devices for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • NF C74-105*NF EN 60406:2015 Cassettes for medical X-ray diagnosis - Radiographic cassettes and mammographic cassettes
  • NF EN 60526:2005 Raccordements par fiche et réceptacle des câbles haute tension pour équipements à rayons X à usage médical
  • NF C74-116*NF EN 60336:2005 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
  • NF EN IEC 60806:2023 Determination of the maximum symmetrical radiation field of equipped sheaths and x-ray sets used in medical diagnosis

RU-GOST R

  • GOST R 59728-2021 Protective devices against X-radiation in medicine. Control methods
  • GOST R 51529-1999 Cassettes for medical X-ray diagnosis. Radiographic and mammographic cassettes
  • GOST 24984-1981 Medical X-ray apparatus. Service symbols
  • GOST 31599-2012 Cassettes for medical X-ray diagnosis. Radiographic and mammogaphic cassettes
  • GOST 26141-1984 X-ray image intensifiers for medical apparatus. General technical requirements. Methods of test
  • GOST 25272-1982 Medical X-ray apparatus. Terms and definitions
  • GOST 26140-1984 X-ray medical apparatus. General specifications
  • GOST 26145-1984 X-ray medical cassetes. General specifications
  • GOST R 50267.28-1995 Medical electrical equipment. Part 2. Particular requirements for the safety of X-ray source assemblies and X-ray tube assemblies for medical diagnosis
  • GOST 26015-1983 Lattices for medical X-radiography. General specifications
  • GOST 30324.28-2002 Medical electrical equipment. Part 2. Particular requirements for the safety of X-ray source assemblies and X-ray tube assemblies for medical diagnosis
  • GOST 26221-1984 Anti-scatter linear grids of medical X-ray apparatus. General specifications
  • GOST R IEC 61267-2001 Medical diagnostic X-ray equipment. Radiation conditions for use in the determination of characteristics
  • GOST 25273-1982 X-ray image intensifier for medical apparatus. Terms and definitions
  • GOST R IEC 60336-2010 X-ray tube assemblies for medical diagnosis. Sharacteristics of focal spots
  • GOST 22091.4-1986 X-ray devices. The methods of measuring of the voltage of X-ray tube
  • GOST 22091.5-1986 X-ray devices. The methods of measuring X-ray tube current

Japanese Industrial Standards Committee (JISC)

SE-SIS

  • SIS SS IEC 637:1986 X-ray equipment - Marking of and accompanying documents for X-ray tu bes and X-ray tube assemblies for medical use
  • SIS SS IEC 658:1986 X-ray equipment - Radiographic intensifying screens for medical use - Dimensions
  • SIS SS IEC 336:1986 X-ray equipment - Characteristics of focal sp?ts in diagnostic X-ray tube assemblies for medical use
  • SIS SS-EN 60 613-1991 X-ray equipment - Electrical, thermal and loading characteristics ef rota?ng anode X-ray tubes for medical diagnosis
  • SIS SS IEC 806:1986 X-ray equipment- Determination ofthe maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • SIS SS-IEC 806:1986 X-ray equipment- Determination ofthe maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • SIS SS IEC 613:1986 X-ray equipment - Electrical. thermal and loading characteristics of rotating anode X-ray tu bes for medical diagnosis
  • SIS SS IEC 526:1986 X-ray equipment - High-voltage cable plug and socket connections for medical X-ray equipment
  • SIS SS IEC 522:1989 X-ray equipment — Inherent filtration of an X-ray tube assembly
  • SIS SS IEC 627:1986 X-ray equipment - Characteristics of anti-scatter grids used in X-ray equipment

Spanish Association for Standardization (UNE)

  • UNE-EN IEC 60806:2023 Determination of the maximum symmetrical radiation field of X-ray tube assemblies and X-ray source assemblies for medical diagnosis (Endorsed by Asociación Española de Normalización in February of 2023.)
  • UNE-EN 60406:2000 CASSETTES FOR MEDICAL X-RAY DIAGNOSIS. RADIOGRAPHIC CASSETTES AND MAMMOGRAPHIC CASSETTES.
  • UNE-EN 60806:2005 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • UNE 20-569-1986 Radiation protection of medical fluids from X-rays from 10Kv to 400Kv
  • UNE-EN 60601-2-28:1996 MEDICAL ELECTRICAL EQUIPMENT. PART 2: PARTICULAR REQUIREMENTS FOR THE SAFETY OF X-RAY SOURCE ASSEMBLIES AND X-RAY TUBE ASSEMBLIES FOR MEDICAL DIAGNOSIS.
  • UNE-EN 61267:1997 MEDICAL DIAGNOSTIC X-RAY EQUIPMENT. RADIATION CONDITIONS FOR USE IN THE DETERMINATION OF CHARACTERISTICS.
  • UNE-EN 60336:1996 X-RAY TUBE ASSEMBLIES FOR MEDICAL DIAGNOSIS. CHARACTERISTICS OF FOCAL SPOTS.
  • UNE-EN 61676:2003 ERRATUM Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology.
  • UNE-EN IEC 61676:2023 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology (Endorsed by Asociación Española de Normalización in June of 2023.)
  • UNE-EN 61676:2003/A1:2009 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • UNE-EN 61676:2003 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • UNE-EN 61223-3-1:2000 Evaluation and routine testing in medical imaging departments -- Part 3-1: Acceptance tests - Imaging performance of X-ray equipment for radiographic and radioscopic systems.
  • UNE-EN 61267:2006 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics (IEC 61267:2005)
  • UNE-EN 60336:2006 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots

YU-JUS

  • JUS N.S5.201-1987 Characteristics of focal spots in diagnostic X-ray tube assemblies for medical use
  • JUS N.S5.204-1980 Kntrance field sizes ofelectro-optical X-ray image intensifiers
  • JUS N.S5.207-1981 High-voltage cable plug and socket connections for medical X-ray eguipment
  • JUS N.S5.203-1980 High-voltage cable plug and socket connections for medicial X-ray equipment

VDI - Verein Deutscher Ingenieure

Korean Agency for Technology and Standards (KATS)

KR-KS

  • KS P 6024-2022 Medical X-ray protective screens
  • KS C IEC 60613-2022 Electrical and loading characteristics of X-ray tube assemblies for medical diagnosis
  • KS B ISO 5576-2022 Non-destructive testing — Industrial X-ray and gamma-ray radiology — Vocabulary
  • KS C IEC 61676-2017 Medical electrical equipment — Dosimetric instruments used for noninvasive measurement of X-ray tube voltage in diagnostic radiology
  • KS B ISO 5576-2016 Non-destructive testing-Industrial X-ray and gamma-ray radiology-Vocabulary
  • KS C IEC 61676-2017(2022) Medical electrical equipment — Dosimetric instruments used for noninvasive measurement of X-ray tube voltage in diagnostic radiology
  • KS C IEC 61262-1-2003(2023) Medical electrical appliances - Characteristics of electro-optical X-ray image intensifiers - Part 1: Determination of incident field of view size
  • KS C IEC 60806-2002(2022) Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis

American Society for Testing and Materials (ASTM)

  • ASTM F3094-14(2022) Standard Test Method for Determining Protection Provided By X-ray Shielding Garments Used in Medical X-ray Fluoroscopy from Sources of Scattered X-Rays
  • ASTM F3094-14 Standard Test Method for Determining Protection Provided by X-ray Shielding Garments Used in Medical X-ray Fluoroscopy from Sources of Scattered X-Rays
  • ASTM E3294-23 Standard Guide for Forensic Analysis of Geological Materials by Powder X-Ray Diffraction

GSO

  • OS GSO IEC 60336:2015 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
  • BH GSO IEC 60806:2016 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • GSO IEC 60806:2014 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • BH GSO IEC 60336:2016 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
  • OS GSO IEC 60806:2014 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • GSO ASTM F3094:2021 Standard Test Method for Determining Protection Provided by X-ray Shielding Garments Used in Medical X-ray Fluoroscopy from Sources of Scattered X-Rays
  • BH GSO ASTM F3094:2022 Standard Test Method for Determining Protection Provided by X-ray Shielding Garments Used in Medical X-ray Fluoroscopy from Sources of Scattered X-Rays
  • GSO IEC 61267:2014 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • BH GSO IEC 61267:2016 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • BH GSO ISO 5576:2016 Non-destructive testing -- Industrial X-ray and gamma-ray radiology -- Vocabulary
  • OS GSO ISO 5576:2013 Non-destructive testing -- Industrial X-ray and gamma-ray radiology -- Vocabulary
  • OS GSO IEC 61267:2014 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • GSO ISO 16129:2014 Surface chemical analysis -- X-ray photoelectron spectroscopy -- Procedures for assessing the day-to-day performance of an X-ray photoelectron spectrometer
  • GSO IEC 60526:2015 High-voltage cable plug and socket connections for medical X-ray equipment
  • GSO IEC 60336:2015 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
  • BH GSO IEC 60526:2016 High-voltage cable plug and socket connections for medical X-ray equipment

US-FCR

Danish Standards Foundation

  • DS/EN 60806:2004 Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis
  • DS/EN 61676:2003 Medical electrical equipment - Dosimetric instuments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • DS/EN 61267:2006 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • DS/EN 61676/A1:2009 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • DS/EN 60406:1998 Cassettes for medical X-ray diagnosis - Radiographic cassettes and mammographic cassettes
  • DS/EN 60336:2005 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots

Association of German Mechanical Engineers

BE-NBN

  • NBN 400-4-1969 Radiation equipment: medical X-ray generators and accessories. Structural features that prevent X-ray radioactivity
  • NBN 400-2-1969 Radiation equipment: medical X-ray generators and accessories. ray tube
  • NBN 400-6-1969 Radiation equipment: medical X-ray generators and accessories. experiment method

VN-TCVN

  • TCVN 6561-1999 Radiation protection for medical installations using X-ray machine
  • TCVN 6596-2000 X ray diagnostic radiography and fluoroscopy.Generator, X ray tube, collimator.Test procedure
  • TCVN 7303-2-28-2009 Medical electrical equipment.Part 2-28: Particular requirements for the safety of X-ray source assemblies and X-ray tube assemblies for medical diagnosis
  • TCVN 6704-2008 Gasoline.Determination of lead by X-Ray spectroscopy

AT-ON

  • ONORM S 5214-1-2002 Medical X-ray equipment - Rules for testing the radiation protection - Part 1: Diagnostic X-ray equipment
  • ONORM S 5213-1983 X-ray protective clothes, X-ray protective clothes with lower shielding-effect and protective devices for medical use of X-rays up to 300 kV
  • ONORM S 5212-1999 Medical X-ray equipment up to 300 kV - Radiation protection rules for the installation
  • ONORM S 5211-1978 Medical X-ray equipment up to 400 kV, radiation protection specifications for the production.
  • ONORM S 5212/AC1-1999 Medical X-ray equipment up to 300 kV - Radiation protection rules for the installa- tion (Corrigendum)

Australian/New Zealand Standard (AU-AS/NZS)

  • AS/NZS 3821:1998 Cassettes for medical X-ray diagnosis - Radiographic cassettes and mammographic cassettes
  • AS/NZS 3200.2.28:1994 Approval and test specification - Medical electrical equipment - Particular requirements for safety - X-ray source assemblies and X-ray tube assemblies for medical diagnosis generators
  • AS/NZS IEC 60336:2022 Medical electrical equipment — X-ray tube assemblies for medical diagnosis — Focal spot dimensions and related characteristics
  • AS/NZS 4274:1995 X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
  • AS/NZS IEC 61267:2022 Medical diagnostic X-ray equipment — Radiation conditions for use in the determination of characteristics
  • AS/NZS 4358:1996 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
  • AS/NZS 3200.2.44:2000 Medical electrical equipment - Particular requirements for safety - X-ray equipment for computed tomography

GOST

  • GOST 24984-2022 Medical X-ray apparatus. Service symbols
  • GOST 25272-2022 Medical X-ray apparatuses. Terms and definitions
  • GOST R 55772-2021 Medical electrical equipment. X-ray equipment for digital radiography and radioscopy. Technical requirements for governmental purchases

HU-MSZT

PL-PKN

  • PN C99282-06-1989 Radiographic medical films Qualitative and usable characteristic of films for X-ray radiography
  • PN C99282-01-1989 Radiographic medical films Introduction and scope ol thc standard

Standard Association of Australia (SAA)

  • AS 1932D:1976 Sizes of film for industrial radiography and x-ray crystallography
  • AS 1630D:1976 Sizes of film for medical radiography

GOSTR

  • GOST R 58453-2019 Medical equipment. X-ray equipment for digital radiography and radioscopy. Significant technical characteristics

Indonesia Standards

  • SNI 16-6649-2002 X-ray tables and stand point for medical use
  • SNI IEC 60601-2-28:2009 Medical electrical equipment - part 2-28: Particular requirements for the safety of X-ray source assemblies and X-ray tube assemblies for medical diagnosis
  • SNI IEC 60331-2:2013 Protective equipment against X-ray radiation in medical diagnostics Part 2: Safety glass

CENELEC - European Committee for Electrotechnical Standardization

  • EN 61267:1994 Medical Diagnostic X-Ray Equipment - Radiation Conditions for Use in the Determination of Characteristics
  • EN 60336:1995 X-Ray Tube Assemblies for Medical Diagnosis Characteristics of Focal Spots

DIN

  • DIN EN 60601-2-28:1995 Medical electrical equipment - Part 2: Particular requirements for the safety of X-ray source assemblies and X-ray tube assemblies for medical diagnosis (IEC 60601-2-28:1993); German version EN 60601-2-28:1993

International Organization for Standardization (ISO)

  • ISO 20289:2018 Surface chemical analysis - Total reflection X-ray fluorescence analysis of water
  • ISO 16129:2012 Surface chemical analysis - X-ray photoelectron spectroscopy - Procedures for assessing the day-to-day performance of an X-ray photoelectron spectrometer

European Committee for Electrotechnical Standardization(CENELEC)

  • EN IEC 61676:2023 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology
  • HD 509 S1-1988 Characteristics of Focal Spots in Diagnostic X- Ray Tube Assemblies for Medical Use
  • EN IEC 61676:2023/AC:2024-02:2024 Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of x-ray tube voltage in diagnostic radiology
  • EN 60406:1997 Cassettes for Medical X-Ray Diagnosis Radiographic Cassettes and Mammographic Cassettes

American National Standards Institute (ANSI)

  • ANSI N43.5-2013 Radiological Safety Standard for the Design of Radiographic and Radioscopic Non-Medical X-Ray Equipment Below 1 MeV
  • BS EN IEC 61676:2023 Medical electrical equipment. Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology (British Standard)

IN-BIS

  • IS 4096-1973 Method for measuring optical focal spot size of X-ray tubes

National Electrical Manufacturers Association(NEMA)

  • NEMA XR 10-1986 Measurement of the Maximum Symmetrical Radiation Field from a Rotating Anode X-Ray Tube Used for Medical Diagnosis
  • NEMA XR 19-1993 Electrical, Thermal and Loading Characteristics of X-Ray Tubes Used for Medical Diagnosis

Lithuanian Standards Office

  • LST EN 61267-2006 Medical diagnostic X-ray equipment. Radiation conditions for use in the determination of characteristics (IEC 61267:2005)