WS/T 645.2-2018 in English
VALIDReference intervals for common clinical immunology tests Part 2: Serum a-fetoprotein, carcinoembryonic antigen, carbohydrate antigen 19-9,carbohydrate antigen 15-3, carbohydrate antigen 125
- Issued on:2018-12-12
- Implemented on:2019-06-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$185.00
本部分规定了中国成人(≥18 岁)血清甲胎蛋白、癌胚抗原、糖链抗原 19-9、糖链抗原 15-3、糖链抗原 125 的参考区间及其应用。
本部分适用于医疗卫生机构临床实验室对血清甲胎蛋白、癌胚抗原、糖链抗原 19-9、糖链抗原 15-3、糖链抗原 125 检验结果的报告,相关体外诊断产品生产厂商可参照使用。
Introduction
Analysis of the core content of the standard
| Item | Unit | Upper reference limit | Key differences |
|---|---|---|---|
| Alpha-fetoprotein (AFP) | ng/mL | ≤7 | Harmonized standard (Traceable to WHO 72/225) |
| Carcinoembryonic antigen (CEA) | ng/mL | ≤5 | Harmonized standard (Traceable to WHO 73/601) |
| CA19-9 | U/mL | 25-43 | Significant differences between systems (Roche/Beckman, etc.) |
Background of Technical Evolution
This standard establishes multi-center data of the Chinese population for the first time (six regions including Northeast China, North China, and East China), achieving the following breakthroughs:
- Screening of 18,000 healthy people: strictly excluding confounding factors such as abnormal BMI and chronic diseases
- CA125 was double-grouped by sex + age for the first time (the threshold difference between pre- and post-menopausal women was 47→25 U/mL)
- Parallel validation by four mainstream detection systems (Roche/Beckman/Siemens/Abbott)
Key Points of Clinical Application
Case Comparison: Interpretation of Abnormal CA125
52-year-old female patient with a test value of 28U/mL:
- Using System a (Roche): Within the reference interval (≤25U/mL)
- Using System d (Abbott): Exceeding the threshold (>22U/mL)
Handling Suggestions: Must be judged in combination with the type of detection system, and methodological comparison should be performed when necessary
Implementation of Validation Specifications
- Sample Requirements: ≥20 healthy controls (balanced in gender and age)
- Outlier Handling: Use the Dixon method (eliminate cases with D/R ≥1/3)
- Passing criteria: Outliers ≤ 10% (n ≥ 20) or ≤ 2 (n = 20)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

WS/T 493-2017 in English
Guide to the estimation of the measurement uncertainty of reference methods in enzymology reference laboratiories
2017-09-06 -

WS/T 472-2015 in English
Oral health survey―Examination methods
2015-09-17 -

WS/T 505-2017 in English
Guideline for evaluation of qualitative test performance
2017-09-06 -

WS/T 573-2018 in English
Algorithm and report of immunological testing for infectious diseases
2018-04-27 -

WS/T 645.1-2018 in English
Reference intervals for common clinical immunology tests Part 1:Serum immunoglobulin G, immunoglobulin A,immunoglobulin M, Complement 3,Complement 4
2018-12-12 -

WS/T 405-2012 in English
Reference intervals for blood cell analysis
2012-12-25 -

WS/T 459-2018 in English
Common used serum tumor marker tests:clinical practice and quality management
2018-12-11 -

WS/T 404.5-2015 in English
Reference intervals for common clinical biochemistry tests—Part 5:Serum urea and creatinine
2015-04-21 -

WS/T 404.9-2018 in English
Reference intervals for common clinical biochemistry tests Part 9: Serum C-reactive protein, prealbumin, transferrin,β2一microglobulin
2018-12-12