Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
safety requirements non-invasive blood pressure monitoring equipment non-invasive blood pressure measurement performance requirements environmental requirements cable line auxiliary facilities rhombus nuts hot pipe radiators
YY 0670-2008 in English

YY 0670-2008 in English

SUPERSEDED

Non-invasive automated sphygmomanometer

  • Issued on:2008-10-17
  • Implemented on:2010-06-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $750.00
$728.00
Standard No: YY 0670-2008
Document status: SUPERSEDED
Superseded by: YY 9706.230-2023 Medical electrical equipment-Part 2-30:Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers
Superseded on: 2026-01-15
Title in English: Non-invasive automated sphygmomanometer
Title in Chinese: 无创自动测量血压计
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2008-10-17
Implemented on: 2010-06-01
ICS Classification: 11.040.30-Surgical instruments and materials
Chinese Classification: C30-Medical apparatus and devices in general
Professional Classification: YY-Pharmaceutics
Related Keywords: safety requirements
non-invasive blood pressure monitoring equipment
non-invasive blood pressure measurement
performance requirements
environmental requirements
Related Topics: blood pressure
Blood
sphygmomanometer
blood pressure measurement
Sphygmomanometer Standard
Sphygmomanometer 80601
Measure
Automatic serum suction
blood pressure measurement
Non-invasive blood pressure monitor
create
blood pressure monitor
non-invasive
Gauge
blood flow measurement
measure blood
automatic counting board
Non-invasive blood pressure equipment
Non-invasive and safer
blood pressure monitor quality
blood pressure monitor quality
blood pressure data
non-invasive measurement
blood pressure measurement method
Sphygmomanometer
automatic ph meter
Automatic flow detection
blood pressure data
non-invasive version
blood pressure measurement method
Non-invasive blood pressure equipment
Sphygmomanometer
automatic sterile
yy0670
automatic urine measurement
instrument blood pressure
How to measure blood pressure with a sphygmomanometer
with automatic blood
non-invasive electrolytes
Mouse blood pressure measurement method
Non-invasive DNA anticoagulation
aami blood pressure monitor
Rat blood pressure measurement method
Fully automatic blood cell counter measurement and calibration
Sphygmomanometer industry
Animal blood oxygen measurement method
Method for measuring blood pressure in rats
Sphygmomanometer group
sphygmomanometer measurement method oscilloscope
yy0670-2008
Correct measurement method of blood pressure monitor


Non-invasive automated sphygmomanometer

1 Scope

This standard establishes safety and validity requirements for all sphygmomanometers, whether automated, or electronic, that are used with an occluding cuff for the indirect determination of arterial blood pressure.

1.1 Inclusions

This standard is applicable to electronic sphygmomanometer completing non-invasive blood pressure measurement via oscillography or other similar methods or other devices having such function, including all devices that inflate and deflate through cuff and sense or display pulsations, flow, or sounds in connection with the measurement, display, or recording of blood pressure.

This standard covers the blood pressure measurement devices for neonatal or newborn through adult categories.

Ambulatory blood pressure monitors, which are portable, lightweight, automated devices worn or carried by the patient that are able to obtain and store the results of repeated determinations of blood pressure and heart rate during activities of ordinary daily living, are included in this standard.

Note: For an explanation of the need for this standard and the rationale for its provisions, see annex A.

1.2 Exclusions

This standard is not applicable to devices for direct, intra-arterial measurement of blood pressure.

The use of automated monitors that measure blood pressure on the finger or through thoracic impedance are not covered in this standard.

2 Normative references

The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments(excluding corrections), or revisions, of any of these publications do not apply to this standard. However parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.

GB 9706.1-2007 Medical electrical equipment - Part 1:General requirements for safety (IEC 60601-1: 1988, IDT)
GB/T 14710-1993 The environmental requirements and test methods for medical electrical equipment
YY 0505-2005 Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standards: Electromagnetic compatibility - Requirements and tests (IEC 60601-1-2: 2001, IDT)
YY 0667-2008 Medical electrical equipment - Part 2-30: Particular requirements for the safety including essential performance of automatic cycling non-invasive blood pressure monitoring equipment (IEC 60601-2-30: 1999, IDT)

3 Terms and definitions

For the purpose of this standard, the following terms and definitions apply.

3.1

adult

individuals greater than 12 years of age

Foreword i
1 Scope
1.1 Inclusions
1.2 Exclusions
2 Normative references
3 Terms and definitions
4 Requirements
4.1 Operating conditions
4.2 Labeling requirements
4.3 life
4.4 Safety requirements
4.5 Performance requirements
4.6 Requirements for inflation source and pressure control valves
4.7 Requirements for the inflatable bladder and cuff
4.8 System leakage
4.9 Environmental requirements
4.10 Electrical safety
4.11 Electromagnetic compatibility
5 Tests
5.1 Test conditions
5.2 Labeling
5.3 Life
5.4 Safety requirements
5.5 Performance requirements
5.6 Requirements for inflation source and pressure control valves
5.7 Requirements for the inflatable bladder and cuff
5.8 System pressure drop
5.9 Environmental test
5.10 Electrical safety
5.11 Electromagnetic compatibility
Annex A (Informative) Rationale for the development of this standard
Annex B (Informative) Verification of overall system efficacy by comparison with manual auscultatory measurements
Annex C (informative) Verification of overall system efficacy by comparison with intra-arterial measurements
Annex D (Informative) Data analysis and reporting
Annex E (Informative) Special considerations for the assessment of ambulatory blood pressure monitoring systems
Annex F (Informative) Statistical considerations
Bibliography
Foreword

Sample only — not a preview of YY 0670-2008
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend