YY/T 1695-2020 in English
VALIDMedical devices for human assisted reproductive technology—Determination of amino acids in human assisted reproductive media
- Issued on:2020-03-31
- Implemented on:2021-04-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$214.00
本标准规定了用氨基酸分析仪法、高效液相色谱串联三重四极杆质谱仪法、高效液相色谱柱前衍生法检测人类辅助生殖技术用培养用液中氨基酸成分。
本标准适用于人类辅助生殖技术用培养用液中所含甘氨酸(GLY)、亮氨酸(LEU)、蛋氨酸(MET)、酪氨酸(TYR)、组氨酸(HIS)、苏氨酸(THR)、丙氨酸(ALA)、异亮氨酸(ILE)、色氨酸(TRY)、胱氨酸(CYS)、赖氨酸(LYS)、天门冬氨酸(ASP)、缬氨酸(VAL)、苯丙氨酸(PHE)、脯氨酸(PRO)、丝氨酸(SER)、谷氨酸(GLU)、精氨酸(ARG)、牛磺酸(TAU)19种氨基酸的定量分析。
Introduction
Analysis of the core content of the standard
This standard specifies the quantitative analysis method for 19 key amino acids in the culture medium used in human assisted reproductive technology, including three detection technology paths: amino acid analyzer, high performance liquid chromatography tandem triple quadrupole mass spectrometer and high performance liquid chromatography pre-column derivatization.
Comparative analysis of detection methods
| Method type | Sensitivity (μg/mL) | Applicable scenarios | Technical features |
|---|---|---|---|
| Amino acid analyzer method (arbitration method) | 1-100 | Conventional detection | Ion exchange chromatography + post-column derivatization, not applicable to samples containing dipeptides |
| HPLC-MS/MS method | 0.05-1 | Trace analysis | Mass spectrometry qualitative and quantitative, mass spectrometry parameters need to be optimized |
| Pre-column derivatization method | 1-100 | Laboratories with limited equipment | OPA/FMOC derivatization, reaction conditions need to be controlled |
Key technical points
1. Sample pretreatment specifications
Note for all methods: Protein precipitation is treated with 4% sulfosalicylic acid or acetonitrile, and the centrifugation speed is 9500g; the amino acid concentration needs to be adjusted to the linear range of each method.
2. Key indicators of quality control
- Correlation coefficient of standard curve ≥0.995
- Relative deviation of parallel samples ≤15-20%
- Blank value must be lower than the detection limit
- Separation degree of amino acid analyzer method ≥85%
Implementation suggestions
Guide to laboratory method selection
1. Arbitration detection: amino acid analyzer method is preferred, and attention should be paid to avoiding dipeptide interference
2. Scientific research analysis: HPLC-MS/MS method is recommended, which can simultaneously obtain mass spectrometry qualitative information
3. Routine monitoring: pre-column derivatization method has lower cost, and derivatization reaction time needs to be strictly controlled
Standard application precautions
• Tryptophan requires special treatment: add NaOH to aid dissolution
• Pay attention to the differences between methods when testing cystine
• Mass spectrometry requires regular mass number calibration (deviation ≤ 0.5Da)
Background of standard evolution
With the development of assisted reproductive technology, the requirements for the control of culture medium components are constantly increasing. This standard systematically regulates the detection methods of 19 amino acids for the first time, including:
• HPLC-MS/MS method reflects the latest development of detection technology
• Pre-column derivatization method retains the applicability of traditional methods
• Clarifies the arbitration method to ensure the resolution of disputed results

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

YY/T 0063-1991 in English
Medical diagnostic X-ray tube assembly focus characteristics
1991-11-21 -

YY 0167-1994 in English
Medical thread
1994-07-02 -

YY 0059-1991 in English
dental handpiece
1991-11-21 -

YY/T 0162-1994 in English
Medical Ultrasound Equipment Grade Series Part 1 Type B Ultrasound Diagnostic Equipment
1994-05-13 -

YY 0188-1993 in English
hip prosthesis
1993-07-19 -

YY 0290.8-2022 in English
Ophthalmic optics-Intraocular lenses-Part 8:Fundamental requirement
2022-10-17 -

YY 0249-1996 in English
Aluminum tube for medicinal ointment
1996-12-30 -

YY/T 0165-2016 in English
Medical heating pad therapy equipment
2016-07-29 -

YY/T 1080-2009 in English
Ophthalmic instruments Direct ophthalmoscopes
2009-12-30 -

YY/T 0106-1993 in English
Medical Diagnostic X-ray machine general technical conditions
1993-02-10