GB/T 1386.4-1997 in English
SUPERSEDEDInsulators for low voltage power lines Part 4: Insulators for trolley overhead lines
- Issued on:1997-04-01
- Implemented on:1998-04-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$253.00
本标准规定了电车线路用绝缘子的产品型式和尺寸、技术要求、试验方法、检验规则以及包装与标志。本标准适用于电车线路和吊车滑触线上作绝缘及固定导电部分用的绝缘子。其安装使用地点的周围环境温度为-40℃~+40℃,海拔不超过1000m。当绝缘子安装使用地点或试验地点的海拔超过1000m时,其试验电压数值应按有关标准规定进行修正。本标准不适用于有破坏瓷和釉的介质中使用的绝缘子。
Scope
This standard specifies the product type and size, technical requirements, test methods, inspection rules, packaging and marking of insulators for tram lines. This standard applies to the insulators used for insulating and fixing conductive parts of tram lines and trolley lines of cranes (hereinafter referred to as insulators). The ambient temperature of its installation and use site is -40℃~+40℃, and the altitude does not exceed 1000. When the altitude of the insulator installation site or test site exceeds 1000m, the test voltage value should be corrected according to the relevant standards. Note: Altitude correction method is under consideration. This standard does not apply to insulators used in media that damage porcelain and glaze.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 44179-2024 in English
Composite hollow core station post insulators with a.c. voltage greater than 1 000V and d.c. voltage greater than 1 500V—Definitions,test methods and acceptance criteria
2024-07-24 -

GB/T 4056-2019 in English
Dimensions of ball and socket couplings of string insulator units
2019-12-10 -

GB/T 7253-2019 in English
Insulators for overhead lines with a nominal voltage above 1 000 V—Ceramic or glass insulator units for a.c.systems—Characteristics of insulator units of the cap and pin type
2019-12-10 -

GB/T 19443-2017 in English
Insulators for overhead lines with a nominal voltage above 1 500 V-Ceramic of glass insulator units for d.c.systems-Definitions,test methods and acceptance criteria
2017-11-01 -

GB/T 34937-2017 in English
Insulators for overhead lines-Composite suspension and tension insulators for d.c. systems with a nominal voltage greater than 1 500 V-Definitions,test methods and acceptance criteria
2017-11-01 -

GB/T 22079-2019 in English
HV polymeric insulators for indoor and outdoor use -- General definitions, test methods and acceptance criteria
2019-12-10 -

GB/T 26869-2011 in English
Insulator-test on indoor post insulator of organic material for systems with nominal voltages greater than 1 000 V up to but not including 300 kV
2011-07-29