GB/T 18244-2022 in English
VALIDTest methods for weathering resistance of building waterproof materials
- Issued on:2022-07-11
- Implemented on:2023-02-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$204.00
《GB/T 18244-2022建筑防水材料老化试验方法》由TC195(全国轻质与装饰装修建筑材料标准化技术委员会)归口,TC195SC1(全国轻质与装饰装修建筑材料标准化技术委员会建筑防水材料分会)执行,主管部门为中国建筑材料联合会。
Introduction
Analysis of the core changes in the new standard
Compared with the 2000 version of the standard, GB/T18244-2022 has been mainly updated: ozone aging and carbon arc lamp methods have been deleted, the test curing conditions have been optimized to "temperature (23±2)℃, humidity 40-60%", and the test verification method for artificial aging has been added. The thermal aging temperature of polymer materials is uniformly set to 80℃±1℃, and the irradiance measurement unit adopts the international standard of "kW·h/m²·nm".
Systematic comparison of aging test methods
| Test type | Applicable standards | Core parameters | Data validity |
|---|---|---|---|
| Hot air aging | Clause 5.3.1 | Asphalt 70℃/Polymer 80℃±1℃ | Grade A fit |
| Xenon arc lamp aging | Clause 6.7.1 | [email protected]/m²·nm | Grade B+ acceleration rate |
| Fluorescent UV aging | 7.7.1 Clause | [email protected]/m²·nm | C-level material verification |
Analysis of key technical elements
Innovation of maintenance conditions
Introduction of the "double darkroom control" system: Group 1 initial test/Group 2 continuous aging/Group 3 darkroom verification, the retention rate calculation adopts the "contemporaneous environmental reference method" to compensate for the influence of natural decay of materials.
Accelerated aging time conversion
According to the formula: {"radiation energy" He= Ec×t}: When the anti-dew type coil requires 5000kJ/m²·nm of 340nm cumulative irradiation, 1042 hours of continuous experiment is required under xenon lamp conditions (converted under standard irradiance conditions).
Project Implementation Suggestions
- Mineral particle surface coil testing requires a >200mm clear spacing anti-reflection device
- Black mark temperature control takes precedence over black board temperature to compensate for the »±5℃ measurement error
- The water quality of the water spray system must meet the industrial pure water standard with a conductivity of ≤5μS/cm

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 41078-2021 in English
Test methods for harmful substances in building waterproofing materials
2021-12-31 -

GB/T 23260-2009 in English
Waterproof sheet with self-adhering layer
2009-03-09 -

GB/T 14686-2008 in English
Asphalt glass felt used in waterproofing
2008-06-30 -

GB 45671-2025 in English
Safety technical specifications for construction waterproof coatings
2025-04-25 -

GB/T 46951-2025 in English
Management specifcations for water conservation for building construction contractors
2025-12-31 -

GB/T 16777-2008 in English
Test methods for building waterproofing coatings
- -

GB 27789-2011 in English
Thermoplastic polyolefin sheets for waterproofing
2011-12-30