Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
oil-immersed convertor transformers convertor transformers single-phase oil-immersed convertor transformers power transformers transformers guidance elements potometric method coli
GB/T 20838-2007 in English

GB/T 20838-2007 in English

VALID

Specification and technical requirements of oil-immersed convertor transformers for HVDC applications

  • Issued on:2007-04-16
  • Implemented on:2007-08-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $100.00
$97.00
Standard No: GB/T 20838-2007
Document status: VALID
Title in English: Specification and technical requirements of oil-immersed convertor transformers for HVDC applications
Title in Chinese: 高压直流输电用油浸式换流变压器技术参数和要求
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2007-04-16
Implemented on: 2007-08-01
ICS Classification: 29.180-Transformers. Reactors
Chinese Classification: K41-Transformer
Professional Classification: GB-National Standard
Related Keywords: oil-immersed convertor transformers
convertor transformers
single-phase oil-immersed convertor transformers
power transformers
transformers
Related Topics: DC transmission technology
Flow instrument parameters
DC transmission technology
HVDC Standard
rheology
direct current transmission
DC Zeeman Technology
streaming xi technology
use oil
Flow Wavelength Parameters
Flow Instrument Parameters
Mass Cytometry Parameters
Air pressure technical parameters
flow voltage action
Prototype Technical Parameters
Regulated voltage in flow mode
Regulated voltage in flow mode
Flow cytometer technical parameters
Streaming single parameter
Stream voltage regulation
Stream voltage regulation
power transmission
Collimator parameters
Technical Parameters
Collimator parameters
direct current transmission
Stream voltage regulation
flow tube high pressure
how to adjust current voltage
The role of voltage in flow cytometry
Flow voltage setting
How does the flow meter determine the voltage
High quality technical parameters
Flow parameter map
Collimator parameters
Flow Technical Parameters
GBT20838
GB/T 20838-2007
Converter Transformer Technical Parameters
Transformer Technology
AC withstand voltage and DC withstand voltage conversion
Transformer DC test steps
GB 6451-1999 Technical parameters and requirements for oil-immersed power transformers
High voltage direct current transmission
GB/T 6451-2023 Technical parameters and requirements for oil-immersed power transformers
Quality of mainstream technical parameters of switches
Transformer DC withstand voltage method
Oil-immersed intelligent power transformer technology
American pole type oil-immersed transformer
Transformer oil sample testing and detection technology
Transformer needs to be replaced
converter transformer
Oil-immersed transformer core grounding

《GB/T 20838-2007高压直流输电用油浸式换流变压器技术参数和要求》由604-2(中国电器工业协会)归口,TC44(全国变压器标准化技术委员会)执行,主管部门为中国电器工业协会。
本标准规定了 500kV级及以下直流输电用油浸式换流变压器的性能参数、技术要求、测试项目、标志、包装、运输和贮存,并在附录A中给出了一些具体产品的有关性能参数实例。本标准适用于 500kV级及以下直流输电用单相油浸式换流变压器。


1 Scope

This standard specifies the performance parameters, technical requirements, test items, marking, packing, transport and storage of ±500 kV or below oil-immersed convertor transformers for DC applications (hereinafter referred to as transformers) and performance parameters examples for some specific products are provided in Appendix A.
This standard is applicable to ±500 kV or below single-phase oil-immersed convertor transformers for DC applications.

2 Normative References

The following normative documents contain provisions which, through reference in this standard, constitute provisions of this standard. For dated references, subsequent amendments (excluding any correction of) to, or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest editions of these documents are applicable. For undated references, the latest editions of the normative documents referred to apply.
GB 1094.1 "Power Transformers--Part 1: General" (GB 1094.1-1996, eqv IEC 60076-1: 1993)
GB 1094.2 "Power Transformers--Part 2: Temperature Rise" (GB 1094.2-1996, eqv IEC 60076-2: 1993)
GB 1094.3 "Power Transformers--Part 3: Insulation Levels, Dielectric Tests and External Clearances in Air" (GB 1094.3-2003, IEC 60076-3: 2000, MOD)
GB 1094.5 "Power Transformers--Part 5: Ability to Withstand Short Circuit" (GB 1094.5-2003, IEC 60076-5: 2000, MOD)
GB/T 18494.2-2007 "Convertor Transformers--Part 2: Transformers for HVDC Applications" (IEC 61378-2: 2001, MOD)
IEC 60296: 2003 "Fluids for electrotechnical Applications--Unused Mineral Insulating Oils for Transformers and Switchgear"

Contents
Foreword I
Introduction II
1 Scope
2 Normative References
3 Schematic Diagram for Wiring Principle of Transformers for 12-pulse Conversion System
4 Performance Parameters
5 Insulation Level
6 Technical Requirements
7 Test Items
8 Marking, Packing, Transport and Storage
Appendix A (Informative) Examples on Relevant Performance Parameters of the Transformer
Appendix B (Informative) Examples of Calculating External Direct Voltage, Polarity Reversal Voltage and External Alternating Voltage of the Valve-side Winding
B.1 Basic Parameters of the Transformer
B.2 External Direct Voltage
Appendix C (Normative) Tests Negotiated between the User Department and the Manufacturing Organization
C.1 Long-time No Load Test
C.2 Oil Flow Electrified Test
C.3 Partial Discharge Measurement During Rotating the Oil Pump

Sample only — not a preview of GB/T 20838-2007
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend