GB/T 34016-2017 in English
VALIDGenerality of rat and termite proof wires and cables
- Issued on:2017-07-12
- Implemented on:2018-02-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$136.00
| Standard No: | GB/T 34016-2017 |
| Document status: | VALID |
| Title in English: | Generality of rat and termite proof wires and cables |
| Title in Chinese: | 防鼠和防蚁电线电缆通则 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2017-07-12 |
| Implemented on: | 2018-02-01 |
| ICS Classification: | 29.060.20-Cables |
| Chinese Classification: | K13-Cable and its accessory |
| Professional Classification: | GB-National Standard |
| Related Keywords: | termite proof wires
ant-proof wires cables introduction in-depth interpretation cables background characteristic code protection level applicable places fs1 significant rat resistance |
| Related Topics: | Wire and Cable
mouse Rodent proof box rat bite test GBT34016 GB/T 34016-2017 Electric anti-rodent optical cable gb/t 34016 |
《GB/T 34016-2017防鼠和防蚁电线电缆通则》由TC213(全国电线电缆标准化技术委员会)归口,主管部门为中国电器工业协会。
Introduction
In-depth interpretation of GB/T 34016—2017 General Rules for Rat-proof and Ant-proof Wires and Cables
Background of Standard Formulation and Analysis of Technical Evolution
With the rapid development of power and communication infrastructure, the demand for laying cables in various complex environments is increasing. Especially in areas with serious rodent and termite infestations, the protective performance of wires and cables is particularly important. The formulation of this standard aims to unify the technical requirements for rodent-proof and ant-proof wires and cables to ensure their reliability and safety in different environments.
In terms of technological evolution, from the initial single protection measure to the current composite protection technology, it reflects the industry's high attention to environmental protection and personal health. By combining chemical and physical protection, the goal of protecting the ecological environment and ensuring cable performance is achieved.
| Characteristic code | Protection level | Applicable places |
|---|---|---|
| FS1 | Significant rat resistance (Level 1) | Applicable to areas with rodent infestation and severe rodent infestation, such as cable trenches and bridges. |
| FS2 | Good rat resistance (Level 2) | Applicable to general rodent infestation environments, such as direct burial underground or cable tunnels. |
| FY1 | Significant anti-termite (level 1) | Used in termite-damaged areas as described in GB/T50768, such as humid areas in the south. |
| FSY11 | Significant anti-rat (level 1) and significant anti-termite (level 1) | Applicable to complex environments with both rat and termite damage. |
Comparison and analysis of standard frameworks
GB/T 34016-2017 standard mainly covers the following aspects:
- Terms and definitions: It clarifies the definitions of wires and cables that are rat-proof, ant-proof, and have both characteristics.
- Product classification and labeling: Standardized product identification is achieved through characteristic codes, which is convenient for market promotion and user selection.
- Technical requirements: Including multi-dimensional technical indicators such as general requirements, rodent-proof characteristics, ant-proof characteristics and rodent-proof and ant-proof composite characteristics.
- Inspection rules: From type testing to continuous effectiveness assessment, ensure the long-term stability of product performance.
Implementation suggestions and practical applications
In actual applications, users should choose the appropriate type of wire and cable according to the specific environment. For example:
- For areas with severe rodent infestation, it is recommended to use cables with FS1 or FSY11 grades.
- In areas with termite infestation, products with FY1 or FSY11 grades are preferred.
- In mixed environments (with both rodent infestation and termites), FSY11 is the best choice.
In addition, users are advised to regularly check the protection performance of the cable, especially in harsh environments, to ensure long-term safety and reliability.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 11017.1-2024 in English
Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV(Um=72.5 kV)and 110 kV(Um=126 kV)—Part 1: Test methods and requirements
2024-09-29 -

GB/T 2952.1-2008 in English
Protective coverings for electric cables - Part 1: General
1982-03-22 -

GB/T 3048.5-2007 in English
Test methods for electrical properties of electric cables and wires—Part 5:Test of insulation resistance
1983-01-01 -

GB/T 5023.3-2008 in English
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 3: Non-sheathed cables for fixed wiring
2008-06-30 -

GB/T 5013.1-2008 in English
Rubber insulated cables of rated voltages up to and including 450/750 V - Part 1:General requiremnts
2008-01-22 -

GB/T 12527-2008 in English
Aerial insulated cables for rated voltages up to and including 1kV
2008-06-30 -

GB/T 29631-2025 in English
Flexible and torsion resistant cables of rated voltages up to and including 1.8/3 kV for wind turbine
2025-02-28