GB/T 3048.5-2007 in English
VALIDTest methods for electrical properties of electric cables and wires—Part 5:Test of insulation resistance
- Issued on:1983-01-01
- Implemented on:2008-05-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$78.00
《GB/T 3048.5-2007电线电缆电性能试验方法 第5部分:绝缘电阻试验》由TC213(全国电线电缆标准化技术委员会)归口,主管部门为中国电器工业协会。
本标准规定了直流比较法和电压-电流法测试绝缘电阻的术语和定义、试验设备、试样制备、试验程序、试验结果及计算、注意事项和试验记录。
1 Scope
This part of GB/T 3048 specifies the terms and definitions, test equipment, sample preparation, test procedures, test results and calculation, cautions and test record of DC comparison method and voltage-current method for the measurement of insulation resistance.
This part is applicable to the measurement of the insulation resistance of electric wires and cables, including DC comparison method and voltage-current method: the measurement range of DC comparison method is (105 ~2×1035)Ω; the measurement range of voltage-current method is (104 ~ 1016)Ω; in general, measurement voltage is (100 ~500)V.
For voltage-current method, if the measured voltage and current are directly shown with ohmmeter on the same instrument, it can be called "megger method".
This part shall be used together with GB/T 3048.1.
2 Normative References
The provisions of the following documents which, through reference in this part of GB/T 3048, constitute provisions of this part. For dated reference, subsequent amendments to (excluding correction contents), or revisions of, any of these publications do not apply. However, the parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards. For undated references, the latest edition of the normative document referred to applies.
Contents
Foreword i
1.Scope
2 Normative References
3 Terms and Definitions
4 Test Equipment
5 Sample Preparation
6 Test Procedures
7 Calculation of Test Result
8 Cautions
9 Test Data Sheet

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 38296-2019 in English
Internal connecting wires and cables of electrical equipment
2019-12-10 -

GB/T 12527-2008 in English
Aerial insulated cables for rated voltages up to and including 1kV
2008-06-30 -

GB/T 33343-2016 in English
Test methods of insulated electric wires for aerospace
2016-12-13 -

GB/T 11017.1-2024 in English
Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV(Um=72.5 kV)and 110 kV(Um=126 kV)—Part 1: Test methods and requirements
2024-09-29 -

GB/T 34016-2017 in English
Generality of rat and termite proof wires and cables
2017-07-12 -

GB/T 5013.1-2008 in English
Rubber insulated cables of rated voltages up to and including 450/750 V - Part 1:General requiremnts
2008-01-22 -

GB/T 14049-2008 in English
Aerial insulated cables for rated voltage of 10kV
2008-06-30 -

GB/T 9326.1-2008 in English
Oil-filled paper or polypropylene paper laminate insulated metal-sheathed cables and accessories for alternating voltages up to and including 500kV - Part 1: Test
2008-06-30 -

GB/T 5441-2016 in English
Test methods for communication cable
2016-04-25 -

GB/T 2952.1-2008 in English
Protective coverings for electric cables - Part 1: General
1982-03-22