《GB/T 34665-2017电机线圈/绕组绝缘介质损耗因数测量方法》由TC301(全国电气绝缘材料与绝缘系统评定标准化技术委员会)归口,主管部门为中国电器工业协会。
Introduction
Standard Development Background and Technology Evolution
GB/T 34665—2017 is a national standard for the measurement method of the dielectric loss factor of motor coils/windings, which aims to standardize the measurement process of rotating motors of different voltage levels. This standard was proposed by the China Electrical Equipment Industry Association and is managed by the National Technical Committee for the Evaluation of Electrical Insulation Materials and Insulation Systems. The background of its formulation mainly stems from the need to evaluate the insulation performance of motors, especially to ensure the safe operation of equipment under high voltage environments.
Core Terminology Explanation
Capacitance
Capacitance is the property of storing charge when there is a potential difference between conductors. Its calculation formula is: C = q/U, and the unit is Farad (F). In motor insulation measurement, the capacitance value reflects the performance of the insulation material.
Dielectric Dissipation Factor
The dielectric loss factor is the ratio of the imaginary part to the real part of the complex relative permittivity, and the formula is: tan δ = ε''/ε'. The smaller the value, the better the insulation performance.
Measurement Principles and Equipment Specifications
| Measurement Items | Requirements | Standard Basis |
|---|---|---|
| Test Voltage Source | Power frequency high voltage test equipment, the output complies with GB/T16927.1. | - GB/T 16927.1 High Voltage Test Technology Part 1 |
| Dielectric loss factor bridge | The measurement error does not exceed 0.2% or 10%, and supports grounded sample measurement. | - GB/T 34665—2017 Section 4.4 |
Comparison of single coil and complete winding measurement
Single coil measurement characteristics
- Applicable to coils with completed insulation curing.
- It is recommended to use a three-electrode system to ensure measurement accuracy.
- Focus on the dielectric loss factor increment under partial discharge starting voltage.
Characteristics of whole machine winding measurement
- Applicable to assembled motor windings.
- Consider the influence of cooling system (such as water cooling) on the measurement results.
- Obtain more accurate dielectric loss factor values through phase measurement and correction calculation.
Implementation suggestions
In actual applications, it is recommended to:
- Measure strictly according to the voltage points specified in the standard (such as 0.2UN, 0.6UN, 1.0UN).
- Repeat the test under high temperature and humidity conditions to evaluate the stability of insulation performance.
- Regularly calibrate the measuring equipment to ensure that its accuracy meets the requirements.