Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
label-free protein chip analysis methods label-free protein chip analysis method label-free protein microarray general analysis regulation practical application cases label-free protein microarray critical flow orifice automotive engine castings equipment concrete sprayer
GB/T 37908-2019 in English

GB/T 37908-2019 in English

VALID

General analysis regulation of the label-free protein microarray based on imaging ellipsometry

  • Issued on:2019-10-18
  • Implemented on:2020-05-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $160.00
$156.00
Standard No: GB/T 37908-2019
Document status: VALID
Title in English: General analysis regulation of the label-free protein microarray based on imaging ellipsometry
Title in Chinese: 基于光学椭偏成像的无标记蛋白质芯片分析方法通则
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2019-10-18
Implemented on: 2020-05-01
ICS Classification: 07.080-Biology. Botany. Zoology
Chinese Classification: C30-Medical apparatus and devices in general
Professional Classification: GB-National Standard
Related Keywords: label-free protein chip analysis methods
label-free protein chip analysis method
label-free protein microarray
general analysis regulation
practical application cases label-free protein microarray
Related Topics: chip
about protein
protein analysis
Two methods of ellipsometer
protein chip
light sheet imaging
microquantum marker protein
Protein Analysis Methods
Ellipsometry-based
Protein chip detection
protein chip technology
protein chip
imaging chip
protein chip
protein chip c1
Blank
Finally the most protein analysis method?
in vitro marker protein
protein chip
Protein chip detection
material imaging
marker protein
spectrophotometric protein
Protein Analysis Methods
photometric protein
spectrophotometric protein
reverse protein chip
Ellipse Imaging Technology
light sheet imaging
in vivo protein labeling
marker protein
Image Analyzer Method
optical chip
Optical eccentric
Optical eccentric
protein spectrometry
imaging chip
Optical eccentric
protein flakes
optical chip
protein molecule
protein chip technology
protein + spectrophotometry
protein photometry
Protein chip detection c6
Optical eccentric 90 degrees
Optical - Polarized
protein a
UV-labeled protein
protein spectroscopy
Optical eccentricity meter
protein analysis
ChIP protein suspension
protein chip c6
Incandescent Imaging Analyzer
protein analysis
Protein Luminosity
Optical rotation of protein
protein photometry
protein composition
Amino acid analysis method in protein
Europium-labeled protein
Core white light technology
Image Analyzer Method
protein spectroscopy
unmarked
GBT37908
Fluorescent protein labeling technology
NH3 protein tag
imaging ellipsometer
How to prepare protein standard curve
Correction methods for proteomic data
Proteomics research methods
protein analysis methods
In vivo imaging analysis methods
The methods that can be used to isolate and purify proteins are
shotgun proteomic approach
How to make a protein standard song
Protein pathway analysis methods
Mass spectrometry-based proteome research methods
Proteomics analysis methods
Elementary school science protein detection method
Principles of protein blotting experimental methods
Is proteomics a molecular biology method?
The difference between protein precipitation method and chromatography method
Fluorescence analysis method for animal live imaging
Protein standard curve
Proteomics analysis methods
Chip foreign matter component analysis method
Common methods for protein iodine labeling
Blank matrix sample analysis and evaluation method
Regulatory documents on analytical method deviations
Mass spectrometry data processing methods for proteomics

《GB/T 37908-2019基于光学椭偏成像的无标记蛋白质芯片分析方法通则》由TC421(全国生物芯片标准化技术委员会)归口,主管部门为国家标准化管理委员会。


Introduction

National Standard of the People's Republic of China GB/T 37908—2019

General Rules for Label-free Protein Chip Analysis Methods Based on Optical Ellipsometry

Background and Significance of Standard Formulation

The label-free protein chip analysis method based on optical ellipsometric imaging technology is an important innovation in the biomedical field in recent years. This technology realizes the detection of molecular interactions without sample labeling through optical measurement with high spatial resolution, and has the advantages of rapidity, sensitivity and high throughput. The formulation of this standard provides unified technical specifications for the research and development, production and application of related instruments, and promotes the widespread application of biochip technology in basic research and clinical medicine.

Standard dimensions Technical requirements Detection methods
Instrument performance indicators Microfluidic pump flow range: $1~\mu L/min \sim 50~\mu L/min$, chip reactor unit volume: no more than $500~\mu L$ Use standard sheets (thickness $1~nm \sim 20~nm$) to perform detection dynamic range test and correlation coefficient calculation.
Detection sensitivity Minimum detection limit: no less than $10~ng/mL$, repeatability error: less than $3\%$ within the chip, less than $10\%$ between chips Verified by dilution of anti-IgG solution and repeated measurement.
System compatibility Supports multi-channel operation, compatible with different sample input and detection requirements. Compare test accuracy with other recognized methods to ensure consistency of results.

Explanation of professional terms and practical application cases

Label-free protein microarray: No physical, chemical or biological labels are required, and detection is performed directly through the specific binding of probe molecules to target molecules. For example, in the screening of disease markers, this technology can detect multiple candidate proteins at the same time.

Surface mass density: The mass of biomolecules on the chip surface per unit area is the core measurement parameter of optical ellipsometry technology.

Standard Framework Comparison and Technology Evolution Analysis

This standard is based on GB/T 1.1-2009 and combines the latest research results in the field of biochips at home and abroad. Compared with traditional fluorescent labeling technology, optical ellipsometry has the following advantages:

  • Non-contact detection: Avoid sample interference and damage.
  • High sensitivity: Can detect $10~ng/mL$ level target molecules.
  • Fast multi-throughput: Supports simultaneous detection of multiple indicators and samples.

Implementation Suggestions

To ensure the effective implementation of the standard, it is recommended that:

  1. Instrument manufacturers conduct R&D and production in strict accordance with technical requirements.
  2. Laboratories need to calibrate and verify the performance of equipment before use.
  3. Strengthen technical personnel training and familiarize themselves with the standard content and testing procedures.

Sample only — not a preview of GB/T 37908-2019
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.