Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
optical cables — part 5023.1-2008 polyvinyl chloride insulated cables 5023.2-2008 polyvinyl chloride insulated cables insulated cables sheathed cables overall design safety review removal vehicles closed-loop copper intrauterine devices
GB/T 5023.4-2008 in English

GB/T 5023.4-2008 in English

VALID

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 4: Sheathed cables for fixed wiring

  • Issued on:2008-06-30
  • Implemented on:2009-05-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $100.00
$97.00
Standard No: GB/T 5023.4-2008
Document status: VALID
Title in English: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 4: Sheathed cables for fixed wiring
Title in Chinese: 额定电压450/750V及以下聚氯乙烯绝缘电缆 第4部分:固套电缆
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2008-06-30
Implemented on: 2009-05-01
Superseding: GB 5023.4-1997 Polyvinyl chloride insulated cables of rated voltages up to and including 450 / 750V - Part 4: Sheathed cables for fixed wiring
ICS Classification: 29.060.20-Cables
Chinese Classification: K13-Cable and its accessory
Professional Classification: GB-National Standard
Related Keywords: optical cables — part
5023.1-2008 polyvinyl chloride insulated cables
5023.2-2008 polyvinyl chloride insulated cables
insulated cables
sheathed cables
Related Topics: Rated voltage 450/750v
Rated voltage iec
iec60227 "polyvinyl chloride insulated cables with rated voltage 450/750v and below"
Round copper wire cables with rated voltage 450/750v and below
gb5023.4
gb t5023.4 2008
gb/t5023.4
GB/T5023.4-2008
Rated voltage iec
Electrical Cable Routing
GB/T 5023.4
GB/T 5023.4-2008
Sheathed cables for fixed wiring
PVC insulated cable
Rated voltage 450
Rated voltage 450/750V and below PVC insulated cables
Rated voltage 450 PVC insulated cable

《GB/T 5023.4-2008额定电压450/750V及以下聚氯乙烯绝缘电缆 第4部分:固定布线用护套电缆》由TC213(全国电线电缆标准化技术委员会)归口,主管部门为中国电器工业协会。
GB/T5023的本部分详细规定了额定电压300/500V 轻型聚氯乙烯护套电缆的技术要求。
所有电缆均应符合GB/T5023.1规定的相应要求和本部分的特殊要求。


1 General

1.1 Scope
This part of GB/T 5023 details the particular specification for light polyvinyl chloride sheathed cables of rated voltage of 300/500 V.
Each cable shall comply with the appropriate requirements given in GB/T 5023.1 and the particular requirements of this part.
1.2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of GB/T 5023. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.
GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 11: Methods for General Application — Measurement of Thickness and Overall Dimensions — Tests for Determining the Mechanical Properties (IEC 60811-1-1:2001, IDT)
GB/T 2951.12-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 12: Methods for General Application — Thermal Ageing Methods (IEC 60811-1-2:1985, IDT)
GB/T 2951.14-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 14: Methods for General Application — Test at Low Temperature (IEC 60811-1-4:1985, IDT)
GB/T 2951.31-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 31: Methods Specific to PVC Compounds — Pressure Test at High Temperature — Test for Resistance to Cracking(IEC 60811-3-1:1985, IDT)
GB/T 2951.32-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 32: Methods Specific to PVC Compounds — Loss of Mass Test — Thermal Stability Test (IEC 60811-3-2:1985, IDT)
GB/T 3956-1997 Conductors of Insulated Cables (idt IEC 60228:1978)
GB/T 5023.1-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 1: General Requirements (IEC 60227-1:2007, IDT)
GB/T 5023.2-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 2: Test Methods (IEC 60227-2:2003, IDT)

Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/T 11017.1-2024 in English

    GB/T 11017.1-2024 in English

    Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV(Um=72.5 kV)and 110 kV(Um=126 kV)—Part 1: Test methods and requirements

    2024-09-29
  • GB/T 4011-2013 in English

    GB/T 4011-2013 in English

    1.2/4.4 mm composite coaxial cable for telecommunication use

    2013-07-19
  • GB/T 14049-2008 in English

    GB/T 14049-2008 in English

    Aerial insulated cables for rated voltage of 10kV

    2008-06-30
  • GB/T 38296-2019 in English

    GB/T 38296-2019 in English

    Internal connecting wires and cables of electrical equipment

    2019-12-10
  • GB/T 12706.1-2020 in English

    GB/T 12706.1-2020 in English

    Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 1: Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)

    2020-03-31
  • GB/T 2952.1-2008 in English

    GB/T 2952.1-2008 in English

    Protective coverings for electric cables - Part 1: General

    1982-03-22
  • GB/T 34926-2017 in English

    GB/T 34926-2017 in English

    Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/ 1 kV

    2017-11-01
  • GB/T 33606-2017 in English

    GB/T 33606-2017 in English

    Flexible and torsion resistant cables of rated voltages from 6 kV(Um=7.2 kV)up to 35 kV(Um=40.5 kV)for wind power generation

    2017-05-12
  • GB/T 18014-2008 in English

    GB/T 18014-2008 in English

    PVC insulated wire for ignition of electric detonators

    2008-06-18
  • GB/T 13849-2025 in English

    GB/T 13849-2025 in English

    Communication cables with polyolefin insulation and moisture barrier polyolefin sheath up to 1MHz

    2025-10-05