Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
type flux paste flux certain aerospace-grade flux content material type rosin type class core classification system classification resistance alloys mineral wool plant thermal pipelines
GB/T 9491-2021 in English

GB/T 9491-2021 in English

VALID

Flux for tin soldering

  • Issued on:2021-12-31
  • Implemented on:2022-07-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $430.00
$418.00

《GB/T 9491-2021锡焊用助焊剂》由TC47(全国印制电路标准化技术委员会)归口,主管部门为工业和信息化部(电子)。


Introduction

Standard Evolution and Industry Significance

GB/T9491-2021, as a new standard replacing the 2002 version, adapts to the industry trend of popularization of lead-free solder and miniaturization of electronics. The newly added requirements of electrochemical migration test and PCB ion residue detection directly respond to the stringent requirements of high-density integrated circuits on soldering reliability.


Core classification system

Classification dimensions2002 edition2021 editionTechnological breakthroughs
Morphological classification Liquid only Liquid()/Solid(S)/Paste(P) Covering SMT mounting process requirements
Activity grading Level 3 (L/M/H) Level 5 (0/1M/0M/1H/0H) Precise control of halogen content
Material type Rosin type Class 4 (RO/RE/OR/IN) Adapt to the development of environmentally friendly materials

Analysis of key technical requirements

5.8 Solderability index

Expansion rate requirements are significantly improved: Lead-free solder is increased from 65% in the 2002 version to 70-80%, verified by the copper plate solder ring test method specified in 6.9.1. In actual applications, after a communication equipment manufacturer used ROM1 type flux, the QFN package soldering yield increased by 12%.

5.13 Electrochemical Migration (ECM)

New test items are added, requiring that after 168h aging:
1) Insulation resistance ≥ 10% of the initial value
2) Conductor spacing reduction ≤ 20%
Verified by the 0.318mm gap comb circuit shown in Figure 3 to prevent the risk of short circuit caused by ion migration in vehicle electronics.


Innovative detection methods

6.10.2.2 Ion chromatography

Compared with the traditional silver chromate test paper method, the Cl/Br/F ion content can be accurately detected to 0.0005%. After adopting this method, the halogen control accuracy of a certain aerospace-grade flux has been improved by 3 orders of magnitude.

6.17 Splash test

The amount of solder wire splash is quantitatively evaluated through the dedicated device in Figure 4 to solve the problem of solder ball contamination in consumer electronics assembly. Actual measurements show that when the Fs value is controlled at ≤0.3%, it can meet most precision assembly requirements.


Implementation recommendations

  1. Material switching: When transitioning from traditional rosin type (RO) to resin type (RE), it is necessary to simultaneously verify the acid value (6.8) and copper mirror corrosion (6.12) performance
  2. Process adjustment: The viscosity of paste flux (P) should be tested according to 6.5 before use, and it is recommended to maintain 800-1200cps at 20℃
  3. Quality control: It is recommended to add 5.15 PCB ion residue batch inspection, and use the megohmmeter method to ensure that the NaCl equivalent is <1.56μg/cm²