QX/T 214-2013 is a professional technical specification formulated by my country's meteorological industry for the pre-treatment and post-treatment of stainless steel sampling cylinders in halogenated greenhouse gas monitoring. The standard specifies the control requirements for core parameters such as temperature, vacuum, and gas replacement during the sampling container processing process.
Comparison of system composition
| Component type | Single-port sampling cylinder system | Dual-port sampling cylinder system |
|---|---|---|
| Temperature control | 100℃ constant temperature | 100℃ constant temperature |
| Vacuum requirement | ≤4Pa | ≤4Pa |
| Processing flow | 3 vacuum pumping-inflating cycles | 4 vacuum pumping-inflating cycles |
| Special treatment | 12 hours balance | 12 hours of gas flushing |
Key technical points
Core steps of pretreatment
- System status detection: ensure that the vacuum degree is less than 4Pa and the filling gas pressure is greater than 1×105Pa
- Heat treatment stage: 3-4 vacuum/gas cycles at 100℃
- The single-port cylinder requires 12 hours of pressure balance, and the double-port cylinder requires 12 hours of flushing at a flow rate of 40mL/min
Post-treatment differences
- The outlet valve must be kept closed during double-port cylinder treatment
- The final filling pressure is uniformly required to be 1×105Pa
- After the treatment, key parameters such as vacuum degree, temperature, and holding time must be recorded
Implementation recommendations
Operational specifications
It is recommended to establish an electronic file of the sampling cylinder to record the following for each treatment:
- Treatment type (pre-treatment/post-treatment)
- System temperature curve
- Vacuum degree reaching standard time
- Filling gas batch number
Quality control
Regularly:
- Calibrating the accuracy of the temperature control unit (±1℃)
- Testing the ultimate vacuum degree of the vacuum pump
- Analyzing the filling gas background concentration
Background of standard evolution
This standard is based on the definition of terms in QX/T 125-2011 and is aimed at Special requirements for stainless steel sampling cylinders in halogenated greenhouse gas monitoring. Compared with earlier methods, the main improvements include:
- Clearly distinguish between single/double-mouth container processing procedures
- Added recommended solutions for low-temperature cold trap water removal
- Standardized information recording form format (Appendix B)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

QX/T 387-2017 in English
Naming specification for meteorological satellite data filename
2017-10-30 -

QX/T 451-2018 in English
Meteorological risk warning levels of small and medium-sized rivers flood induced by torrential rain
2018-11-30 -

QX/T 251-2014 in English
Quality grades of L0 and L1 data for FY-3 meteorological satellit
2014-10-24 -

QX/T 223-2013 in English
Meteorological archives classifying and coding
2013-12-22 -

QX/T 554-2022 in English
Performance state and alarm of weather radar-XML format
2022-12-06 -

QX/T 235-2014 in English
BUFR coding for standard AMDAR data
2014-07-25 -

QX/T 518-2019 in English
Specifications for data exchange of meteorological satellite-XML format
2019-12-26 -

QX/T 148-2020 in English
Specification for high performance computer systemtest and evaluation in the meteorological field
2020-07-31 -

QX/T 30-2021 in English
Technical specifications for lightning protection of automatic weather stations
2021-07-16 -

QX/T 552-2022 in English
Data format for air negative ion observations-BUFR
2022-12-06