Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
industrial enzyme preparations industrial enzyme preparation 5-7 gradient points control enzyme requirements enzyme activity indicators accepted enzyme activity seconds/frame video extraction + ai recognition permission management basic role division fitness equipment scenic environment use scopethis standard
GB/T 35538-2017 in English

GB/T 35538-2017 in English

VALID

Technical guides for industrial enzyme preparations assay

  • Issued on:2017-12-29
  • Implemented on:2018-07-01
  • File Format:PDF
  • Delivery:Within 1 day
Price(USD): $248.00
$241.00

《GB/T 35538-2017工业用酶制剂测定技术导则》由TC64(全国食品工业标准化技术委员会)归口,TC64SC5(全国食品工业标准化技术委员会工业发酵分会)执行,主管部门为国家标准化管理委员会。


Introduction

Standard Framework and Technology Evolution

GB/T 35538-2017 is my country's first national standard for industrial enzyme preparation assay technology. It integrates the technical requirements of existing industry standards such as QB/T 1803, and introduces the internationally accepted enzyme activity assay verification system. The standard took three years to formulate and was led by the China Food Fermentation Industry Research Institute and completed jointly by leading domestic and foreign companies such as Novozymes.


Analysis of core assay elements

Key parametersSelection principlesTypical rangeExample
Substrate Minimum Km value/strong specificity 10-100 times of Km Casein (protease)
Temperature ±10℃ gradient test 35-60℃ Animal enzyme 35-40℃
pH Binding stability curve 4.5-7.5 Pullulanase pH4.5
Buffer system Within the range of pKa±1 0.05-0.2mol/L Acetic acid-sodium acetate system

Enzyme activity determination standardization process

Critical control points

  1. Standard curve verification: R²≥0.98, set 5-7 gradient points
  2. Control enzyme requirements: Contaminated enzyme needs to be detected by ELISA (<50,000ng/g)
  3. Precision control: Repeatability RSD≤4-10%

Comparison of typical methods

Method typePrincipleApplicable enzymesPrecision requirements
DNS method Reducing sugar color development Pullulanase CV≤12%
UV method Substrate absorbance change Catalase CV≤8%
Dyeing substrate method Color product precipitation Cellulase CV≤10%

Implementation difficulties and solutions

Common problems

  • Matrix interference: Acarbose is recommended to inhibit the activity of impurities
  • Temperature drift: A constant temperature water bath with an accuracy of ±0.1℃ is required
  • Substrate batch differences: 24-sample cross-validation is required

Method validation requirements

Need to meet the following requirements

  • Accuracy 95-105% (referenced to standard substances)
  • Intermediate precision ≤10%
  • Linear range ≥2.5 orders of magnitude

Industrial application connection

The standard places special emphasis on the correlation verification between enzyme activity indicators and actual application performance. A supplementary testing plan should be established when the following situations occur:

  1. Synergistic/antagonistic effects exist in the complex enzyme system
  2. The difference between industrial reaction conditions and test conditions is greater than 15%
  3. The product contains auxiliary materials that affect the determination

It is recommended to use SDS-PAGE electrophoresis combined with HPLC for impurity monitoring.