本标准规定了粮食及其制品有机磷类和氨基甲酸酯类农药残留的快速定性检测的原理、试剂和材料、仪器和设备、样品制备和结果分析等内容。
本标准适用于粮食及其制品有机磷类和氨基甲酸酯类农药残留的快速定性检测。
本标准的方法检出限见附录A。
Introduction
Core Value and Application Scenarios of the Standard
This standard aims at the risk control needs of pesticide residues in the grain circulation link, and establishes a rapid screening system based on fluorescence detector. Compared with the traditional chromatographic method, the detection time is shortened from 4-6 hours to 30 minutes, which is particularly suitable for on-site rapid screening in the grain storage and processing links.
In-depth Analysis of Technical Principles
The detection is based on the enzyme inhibition method: organophosphorus/carbamate pesticides inhibit the activity of insect esterases, resulting in a decrease in the hydrolysis rate of fluorescent substrates.
| Technical parameters | Traditional method | This standard method |
|---|---|---|
| Detection principle | Chromatographic separation | Enzyme inhibition reaction |
| Sensitivity | 0.01-0.1μg/kg | 0.1-75μg/kg |
| Sample cost | 200-300 yuan | 30-50 yuan |
Key operating points
Case study: When a grain depot tested dichlorvos residues in rice, it was found that the following operational differences had an impact on the results:
- When the incubation temperature was 35℃±1℃, the inhibition rate deviation was ≤5%
- Adding the fluorescent substrate for more than 30 seconds would cause the signal to attenuate by 15-20%
- When the sample size did not reach the 20-mesh standard sieve, the extraction efficiency decreased by 30%
Implementation suggestions and precautions
1. Matrix difference compensation: Different grain varieties should refer to Appendix C to select the corresponding limit enzyme inhibition rate. For example, the dichlorvos limit in brown rice is 45.6%, while that in corn is 50.6%
2. False positive processing: For suspected positive samples (inhibition rate exceeds the standard), GC-MS/MS should be used for confirmation in combination with the limit requirements of GB2763
3. Equipment calibration: Fluorescence detector needs to be verified monthly with standard products to ensure the accuracy of the 460-550nm excitation wavelength and 590nm emission wavelength