GB/T 38163-2019 in English
VALIDDetermination of allergenic protein—LC-MS/MS method
- Issued on:2019-10-18
- Implemented on:2019-10-18
- File Format:PDF
- Delivery:Via email within 1~3 business days
$243.00
《GB/T 38163-2019常见过敏蛋白的测定 液相色谱-串联质谱法》由TC387(全国生化检测标准化技术委员会)归口,主管部门为国家标准化管理委员会。
Introduction
Analysis of standard technical framework
| Technical elements | GB/T 38163-2019 | International general method | Innovation |
|---|---|---|---|
| Detection objects | 7 types of allergen proteins | Single-type allergen detection | Multi-target simultaneous screening |
| Feature markers | 14 characteristic peptides | Intact protein detection | TrypsinEnzymatic digestion strategy |
| Quantitative linear range | 5-1600mg/kg | 50-1000mg/kg | Sensitivity increased by 10 times |
Core technology innovation
Characteristic peptide screening system
The 14 characteristic peptide databases established in the standard (see Table A.1) have the characteristics of strong specificity:
- Milk α-S1 casein: FFVAPFPEVFGK (m/z 692.9→920.5)
- Peanut Ara h 3/4: RPFYSNAPQEIFIQQGR (m/z 684.4→601.3)
Mass spectrometry parameter optimization
Take triple quadrupole mass spectrometer as an example, the key parameter settings are:
| Ionization mode | ESI+ |
| Collision energy | 20-48eV (adjusted according to the peptide segment) |
| Ion source temperature | 500℃ |
Method validation data
Performance index comparison
| Allergens | Detection limit (mg/kg) | Quantification limit (mg/kg) | Recovery range (%) |
|---|---|---|---|
| Milk | 1.0 | 5.0 | 75.6-108.5 |
| Peanut | 2.5 | 10.0 | 70.9-216.0 |
Matrix Interference Solution
Using ultrafiltration centrifuge tubes (10kD molecular weight cutoff) and Tris-HCl buffer system, we can effectively eliminate:
- Sugar interference in biscuit matrix
- Polyphenols in chocolate
Implementation Recommendations
Critical Control Points
- Enzyme hydrolysis time is strictly controlled at 4±0.5h (37℃)
- Use freshly prepared DTT solution (≤1 month)
- Mass spectrometer calibration must meet the resolution ≥12000
Standardized operation
It is recommended to establish a LC-MS/MS system suitability test:
| Sensitivity | S/N≥10 (1pg reserpine) |
| Mass accuracy | ≤3ppm |

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 47142-2026 in English
Determination of molecular weight of polysaccharides—Size exclusion chromatography with multi-angler laser light scattering method
2026-01-28 -

GB/T 33681.1-2017 in English
Methods to prepare samples for high-throughput gene sequencing—Part 1:Preparing samples of animal tissues
2017-05-12 -

GB/Z 260-2026 in English
Biomimetics—Ontology-Enhanced Thesaurus (OET) for biomimetics
2026-08-27 -

GB/T 37402-2019 in English
Biomimetics—Biomimetic structural optimization
2019-05-10 -

GB/T 35535-2017 in English
Detection of genetically modified components in soybean and canola―Membrane-based gene-chip method
2017-12-29 -

GB/T 27990-2011 in English
Fundamental terms for biochips
2011-12-30 -

GB/T 42076.2-2025 in English
Biotechnology—Cell Counting—Part 2: Experimental design and statistical analysis to quantify counting method performance
2025-10-31 -

GB/T 41812-2022 in English
General rules for performance testing of automatic liquid handling workstation
2022-10-12 -

GB/T 39100-2020 in English
Determination of antioxidant activity for polypeptides—DPPH and ABTS methods
2020-09-29