National Standard of the People's Republic of China GB/T 34800—2017 Proteinase K Enzyme Activity and Impurity Detection Method
1. Standard Overview
This standard specifies the enzyme activity and impurity detection methods of proteinase K, which is applicable to the production and quality control of biochemical reagent products. This standard was proposed and coordinated by the China National Institute of Standardization, and the drafting units include many universities, scientific research institutions and enterprises.2. Background of Standard Formulation
Proteinase K is an important biochemical reagent and is widely used in the field of biotechnology. With the expansion of its application scope, the requirements for product quality and detection methods are also increasing. The formulation of this standard aims to standardize the detection process and ensure the consistency and reliability of the product.3. Detection Principle and Method
Proteinase K hydrolyzes bovine hemoglobin by catalyzing the cleavage of peptide bonds to produce phenolic amino acids. Under alkaline conditions, Folin's reagent reduces it to molybdenum blue and tungsten blue, and the absorbance change is proportional to the tyrosine content, thereby calculating the enzyme activity.4. Comparison table of standard frameworks
The following table compares the standard frameworks for detection methods of proteinase K and other related enzymes (such as RNase and DNase):| Enzyme name | Detection principle | Scope of application | Reference standard |
|---|---|---|---|
| Protease K | Peptide bond cleavage and Folin reagent colorimetry | Production and detection of biochemical reagents | GB/T 34800—2017 |
| RNase | RNA hydrolysis and phosphomolybdic acid reduction | Detection of biochemical reagents | GB/T 34222 |
| DNase | DNA hydrolysis and colorimetric determination | Detection of biochemical reagents | GB/T 34801 |
5. Implementation suggestions
To ensure accurate test results, it is recommended to pay attention to the following points when implementing this standard:- Instrument calibration: Use a constant temperature water bath, pH meter and spectrophotometer that meet the accuracy requirements.
- Reagent preparation: Folin reagent must be prepared strictly according to the ratio and stored away from light.
- Operation specifications: Strictly abide by the reaction time and temperature conditions to ensure the reliability of experimental data.
Sample only — not a preview of GB/T 34800-2017

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 38475-2020 in English
Detection of mycotoxins in pigment—Rapid quantitative method of colloidal gold strip test
2020-11-19 -

GB/T 40183-2021 in English
Determination of DNA methylation—Pyrosequencing
2021-05-21 -

GB/T 38790.1-2020 in English
Efficacy evaluation of bioactive peptides—Part 1:General principles
2020-04-28